Phau Ntawv Qhia

Slimline-RF V1\V2 Setup & Pairing
Step 1 Setup. With the thermostat turned OFF:
• Press & hold the Clock button until you see two sets of numbers appear *................................................................
The small number 01 in the top right corner of the LCD is the feature number.
• Press Clock repeatedly until you see feature 06 (Receiver Type) .....................................................................................
The options within feature 06 are: 00 = UH8-RF or 01 = UH8-RF v2/RF-Switch receiver.
• Use the Up/Down keys to set feature 06 to 01 (UH8-RF V2/RF-Switch) ...............................................................
• Press Clock again until you see feature 07 (Receiver Address) .........................................................................................
You can now select a zone number from 01-08. To save confusion, set this address to the same zone
number you will be pairing to on the UH8-RF V2. If you have a second UH8-RF V2, you would choose
numbers 9 to 16 and so on for each additional wiring centre.
• Use the Up/Down keys to set feature 07 to 01 ..............................................................................................................
(You must set a unique zone number address for each thermostat installed).
• Press A to confirm settings and the display will go blank .................................................................................................
If in mode 02, the secondary timer will automatically be paired to Hot Water channel.
Step 2 Pairing.
• On the UH8-RF V2, press and hold the desired zone pairing button for 5 seconds or until the zone light flashes
steadily.
With the thermostat turned OFF, press & hold the A button for 5 seconds..................................................................
The thermostat will send a signal for 1 minute and will flash the RF signal icon**....................................................
If pairing is successful, the flashing light on the UH8-RF V2 will go out almost immediately.
If pairing is unsuccessful, check features 06 to 07 have been configured correctly. To eliminate a possible signal
issue, reposition the thermostat closer to the receiver and repeat the pairing process again.
Note: the maximum number of Slimline-RF thermostats on this system is 32.
*Feature Menu
**Active Pairing
Wiring Centre2 12