Operating instructions

♦♦♦
13
English
VESA DPMS Standard
H. sync V. sync Video State
Off On Blank Stand-by
On Off Blank Suspend
Off Off Blank Off
3.3 Energy Declaration
This monitor is equipped with a function for saving of energy which supports
the VESA Display Power Management Signaling (DPMS) standard. This
means that the monitor must be connected to a computer which supports VESA
DPMS to fulfil the requirements in the NUTEK specification 803299/94. Time
settings are adjusted from the system unit by software. From indicated inac-
tivity to Power Saving Position A2 the total time must not be set to more than
70 minutes.
1. VESA Power-Management Proposal
2. Power Consumption (120/230 Vac)
NUTEK VESA state LED indicator Power Consumption
Normal operation On Green <130W
Power Saving
Position A1
Suspend Amber <15W
Power Saving
Position A2
Off Amber <8W