3. Installing And Using SWH-2024D NWay Switching Hub
3.1 Installing The SWH-2024D NWay Switching Hub
The hub does not require software configuration. Users can immediately use any of
the features of this product simply by attaching the cables and turning the power on.
3.1.1 Desktop Installation
To locate the switching hub on the desktop and place the hub on a clean, flat desk
or table close to a power outlet. Plug in all network connections and the power cord, then
the system is ready.
When deciding where to put the switching hub then you must ensure:
!"
It is accessible and cables can be connected easily
!"
Cabling is away from:
Sources of electrical noise such as radios, transmitters and broadband amplifiers
Power lines and fluorescent lighting fixtures.
!"
Water or moisture can not enter the unit
!"
Air flow around the unit and through the vents in the side of the case is not
restricted (company recommend that you provide a minimum of 25mm inch
clearance)
To prolong the operational life of your units:
!"
Never stack units more than eight high if freestanding.
!"
Do not place objects on top of any unit or stack
!"
Do not obstruct any vents at the sides of the case
3.1.2 Rack-Mount Installation (only for 19 inch product)
The switching hub may standalone, or may be mounted in a standard 19-inch
equipment rack. Rack mounting produces an orderly installation when you have a
number of related network devices. The switching hub is supplied with two mounting
brackets and screws. These are used for rack mounting the unit.
Rack Mounting the Switching Hub
The switching hub should be able to fit in the 19 inch rack.
1. Disconnect all cables from the switching hub before continuing.
2. Place the unit the right way up on a hard, flat surface with the front facing toward you.
3. Locate a mounting bracket over the mounting holes on one side of the unit.
4. Insert the screws and fully tighten with a suitable screwdriver.
5. Repeat the two previous steps for the other side of the unit.
6. Insert the unit into the 19" rack and secure with suitable screws (not provided).
7. Reconnect all cables.