User Manual
MCN Remote Comparator Display Appendix A
CTI Products, Inc. Changing Status Message Text
68-10856-210
89
Category Left Mouse or V
Keyboard Button
Right Mouse or D
Keyboard Button
DEFAULT Momentary Latched
ALARMS Off or Disabled Off or Disabled
CONTROL Latched Latched
Table 8 - Category Mouse/Keyboard Controls
Assume in our example system that all outputs on the three MCN I/O modules are
inactive. If the left mouse button is pressed when the mouse cursor is on the
Winton Hills
display position, the VOTE output that is connected to the
Winton
Hills
receiver will change to active. The MCNRCD screen will display
Vote
for
the receiver’s state. When the left mouse button is released, the VOTE output
will return to inactive. The receiver’s status display on the MCNRCD screen will
be blank. This is because the left mouse button for the Comparator I/O Module is
programmed for momentary operation in the category DEFAULT.
If the right mouse button is pressed when the mouse cursor is on the
Light 1
display position, the Input/Output Control Module DISABLE line that is
connected to the
Light 1
output will change to active. The output’s status display
on the MCNRCD screen will show
Run
. This I/O line is the line that is
controlled by the DISABLE input status signal for that display position. When the
right mouse button is released, the output remains active. The output will not
return inactive until the right mouse button is pressed again. . The output’s status
display on the MCNRCD screen will then change to blank.