User Manual

MCN Remote Comparator Display Appendix D
CTI Products, Inc. Modem Configurations
68-10856-210
111
Factory Options 1 Leased Line Modem Dial Up Line Modem
Modem Options Modem Options Modem Options
DTE Parameters
Async / Sync Data Async Async
DTE RATE 38400 38400
Char Size 8 Bit 8 bit
Parity None None
Dial Method Async Commanded Dialer Async Commanded Dialer
AT Command Set Enabled Enabled
DTR Response Ignore (&D) DTR Resets (&D3)
DSR State Forced High Forced High
DCD State Forced High (&C) Normal (&C1)
CTS State Forced High Forced High
DTE Fallback Disabled Disabled
Options Retained at Options Restored at Options Restored at
Test Parameters
Bilateral Analog Loop Disabled Disabled
Bilateral Digital Loop Disabled Disabled
DTE Local Test Disabled Disabled
DTE Remote Test Disabled Disabled
Remote Commanded Test Enabled Enabled
Test Time-out Off Off
Dial Line Parameters
Tone Dial / Pulse Tone Dial Tone Dial
Auto Dial #1 #1
Wait For Dial Tone / Blind Wait For Dial Tone Wait For Dial Tone
Pause Delay 2 Sec 2 sec
Call Time-out 30 Sec 30 sec
Answer on Ring 1 1
801 V.32 Time-out Long Long
Autocallback Disabled Disabled
Speaker Options
Volume Medium Medium
On / Off Control Until Carrier Detect Until Carrier Detect
Additional AT Options
Additional AT Options
Echo Off (E) **
** Programmable only with a communications program using the modems DCE port.