User Manual
MCN Remote Comparator Display Appendix D
CTI Products, Inc. Modem Configurations
68-10856-210
108
12. Appendix D - Modem Configurations
UDS V.3225 MODEM CONFIGURATION SHEET
Configuration Procedure for V.3225 Modems version 2.12.12:
1. Load Factory Option Set #1.
2. Change the required settings for your operating mode except the Options Restored at
Disconnect. ( See * ) All options different than option set #1 are highlighted.
3. Save Settings.
4. If you are using a Dial-up mode Set Options Restored / Retained as needed.
5. If you are using leased line mode, connect both modems together over the leased line or
test line and wait until the modems train and connect. Once the modems are on line set the
Options Retained / Restored as required.
6. Save Settings.
Menu Options 1 Leased Line Modem Dial Up Line Modem
Modem Parameters Modem Parameters Modem Parameters
DCE Rate 9600 Trellis 9600 Trellis
Normal Originate / Forced
Answer
-HIB Modem
-PC Modem
Forced Answer
Normal Originate
Forced Answer
Normal Originate
V.32 Fast Train Disabled Disabled
Auto Retrain Enabled Enabled
Transmit Clock Internal Internal
Dial Line / Lease Line Leased Line Dial Line
- 4-Wire (Recommended) -
- TX Level is 0 dbm -
- Dial Backup is -
- LookBack Timer is 15 -
Jack Type RJ11 (permissive) RJ11 (permissive)
Line Current Disconnect Long Long
Long Space Disconnect Disabled Disabled
V.32 Cleardown Don’t Care Don’t Care
V.22 Guard Tone Disabled Disabled
MNP Options
MNP Protocol Enabled (\N3) Enabled (\N3)
DTE Speed
-HIB Modem
-PC Modem
Constant DTE Speed
Constant DTE Speed
Constant DTE Speed
Constant DTE Speed
Auto Fall Back Normal Normal
Flow Control RTS/CTS (\Q3) RTS/CTS (\Q3)
XON/XOFF Pass Through Don't Care Don't Care
Data Compression Enabled(%C1) Enabled(%C1)
Inactivity Timer Off Off
MNP Break Control 5 5
DTE Parameters
Async / Sync Data Async Async
DTE RATE 19200 or 9600 19200
Char Size 8 Bit 8 Bit
Parity No No
Dial Method Async Commanded Dialer Async Commanded Dialer