User Manual
MCN Remote Comparator Display Appendix A
CTI Products, Inc. Changing Status Message Text
68-10856-210
94
Creating 4 sub-categories
Table 10 shows how four sub-categories can be created by reserving the FAIL and
the DISABLE input status signals (binary weight 40 hex and 20 hex) for the
selector. Up to 4 status messages can be defined for each sub-category, with the
VOTE and RECEIVE input status signals selecting between the status messages
in each sub-category.
Input
Value
Field
Sub-
category
Sub-Category
Selector I/O Bits
FAIL DISABLE
Active Status Signals
00 0 0 0 -
01 0 0 0 VOTE
04 0 0 0 RECEIVE
05 0 0 0 RECEIVE + VOTE
10 1 0 1 -
11 1 0 1 VOTE
14 1 0 1 RECEIVE
15 1 0 1 RECEIVE + VOTE
40 2 1 0 -
41 2 1 0 VOTE
44 2 1 0 RECEIVE
45 2 1 0 RECEIVE + VOTE
50 3 1 1 -
51 3 1 1 VOTE
54 3 1 1 RECEIVE
55 3 1 1 RECEIVE + VOTE
Table 10 - 4 Sub-categories / 4 States Each
Note: In Table 10, any bit or input status signal shown as a 1 is an active input
signal and any bit shown as a 0 is an inactive input signal. For the MCN system,
all I/O signals are active low, so any active input status signal is low at the CIB or
IOB I/O connector and any inactive input status signal is high at the CIB or IOB
I/O connector.