Owner's manual

MCNConfig Program: Master-Sub Comparator Configuration
116 68-11824-210
For example, if you want to display a system in two ways:
Virtual Comparator A (using Master A comparator)
Virtual Comparator B (using Master B comparator)
You would set up a one tab for each Virtual Comparator as shown below:
Virtual Comparator A
Sub Comparator A Sub Comparator B Sub Comparator C Sub Comparator D-1 Sub Comparator D-2
Site 1 Site 9 Site 17 Rx Site 25 Site 33
Site 2 Rx Site 10 Site 18 Vote Site 26 Site 34
Site 3 Rx Site 11 Rx Site 19 Rx Site 27 Rx Site 35 Dis
Site 4 Rx Site 12 Site 20 Site 28 Rx Site 36
Site 5 Rx Site 13 Site 21 Rx Site 29 Site 37
Site 6 Rx Site 14 Rx Site 22 Site 30 Site 38
Site 7 Site 15 Rx Site 23 Rx Site 31 Site 39
Site 8 Dis Site 16 Site 24 Site 32 Site 40
Virtual Comparator B
Sub Comparator A Sub Comparator B Sub Comparator C Sub Comparator D-1 Sub Comparator D-2
Site 1 Site 9 Site 17 Rx Site 25 Site 33
Site 2 Rx Site 10 Site 18 Rx Site 26 Site 34
Site 3 Rx Site 11 Rx Site 19 Rx Site 27 Rx Site 35 Dis
Site 4 Vote Site 12 Site 20 Site 28 Rx Site 36
Site 5 Rx Site 13 Site 21 Rx Site 29 Site 37
Site 6 Rx Site 14 Rx Site 22 Site 30 Site 38
Site 7 Site 15 Rx Site 23 Rx Site 31 Site 39
Site 8 Dis Site 16 Site 24 Site 32 Site 40
The Display Windows are similar, with the following differences:
Master Comparator A is voting Sub Comparator C and using Rx 18.
Master Comparator B is voting Sub Comparator A and using Rx 4.
If the Dispatcher had the A-B switch in position "A", he would hear audio from Rx 18. If he had it in the
"B" position, he would be hearing Rx 4.