Environmental Considerations
The operating environment for the IP Gateway must be within limits noted in the specifications, as well as other
conditions. Do not install equipment in an area where any of the following exist:
Extreme temperature and humidity beyond limits listed in the specifications
High EMI (Electro-Magnetic Interference) or RFI (Radio Frequency Interference)
High dust concentration
High ESD (Electrostatic Discharge)
Extreme Vibration
RF Interference
To prevent RF interference, Mobile radio antennas should be kept a minimum of 24 feet from the RadioPro IP Gateway
when in high-power mode, or a minimum of 12 feet when in low-power mode. Portable radios should be kept a
minimum of 6 feet from the RadioPro IP Gateway.
Lightning and Fire Protection
Lightning protection should be implemented at both the equipment and at the point of entry of the building. Lightning
protection and power transient protection should be implemented to reduce the risk of fire caused by these phenomena.
Circuit breakers and fuses offer the best methods for preventing extended over-current and over-voltage conditions.
Power Requirements
When using the supplied AC power adapter, each IP Gateway requires 100-240VAC, 200mA maximum.
When connecting a DC supply directly to the IP Gateway, each IP Gateway requires the following input, depending on
the IP Gateway Serial Number:
IP Gateway Serial Numbers Voltage Range
1000 through 3153 11.5 – 12.5 VDC
3154 and higher 12.0 – 32.0 VDC
RadioPro Version Match
RadioPro Dispatch clients, Talk clients, and IP Gateways must have compatible versions in order to communicate with
each other. Compatibility can be ensured when the first two digits of the version match. (The third digit indicates a minor
revision, and does not need to match.) See Appendix for tables of compatibility.
Static IP Address
Each RadioPro IP Gateway requires a static IP address. The IP Gateway must have IP Network Parameters configured
using ICU.exe (IP Configuration Utility) before connecting to an active network. Contact your IT administrator to provide
a static IP Address for each RadioPro IP Gateway, along with its Subnet Mask and Default Gateway.