Installation guide
RadioPro IP Gateway Installation and Configuration Guide
32
Step 3. Configure RadioPro IP Gateway
Note: Before continuing, ensure that WiFi connection has been disabled in the PC or Laptop being used to
configure the IP Gateway.
The RadioPro ICU (IP Configuration Utility) must be used to configure each RadioPro IP Gateway with the necessary
parameters. Configuration of each RadioPro IP Gateway must be performed before connecting the IP Gateway to a local
area network:
Configure the IP Gateway as follows:
a. Use an Ethernet cable to connect the RJ45 connector on the rear of the RadioPro IP Gateway to a local PC or laptop
to be used for configuration.
b. Power up the RadioPro IP Gateway AND the Control Station radio.
c. Run the ICU.exe application. (See What is Included on Page 10 to locate this utility
program.) The window shown to the right will be displayed:
d. Click on Read Device, then click Auto Find to display the following
Configuration window.
If the connected IP Gateway is not listed in the above window, choose Manual from the Read Device menu. If
Manual method is used, the IP Address of the IP Gateway must be known. (The Factory Default IP Address is
10.15.1.101) The Manual method must be used if the connection between the PC and the IP Gateway involves an
IP router.
e. Double-click on a device in the above list to display the following Device Configuration window:
Tip:
Expand the window to
view the help
information near the
bottom.
MAC Address