Installation guide
RadioPro IP Gateway Installation and Configuration Guide
30
Step 1d. for MOTOTRBO
Configure Motorola Repeaters for Enhanced GPS Option
If RadioPro Dispatch will map GPS data for more than 25 radios per repeater slot, then it is recommended to dedicate one
or more Data Revert slots for this GPS data. Further, repeaters with Data Revert slots should have the “Enhanced GPS
Option” enabled. Contact Motorola for ordering information for this option.
Configure the “Enhanced GPS Option” in the repeater using Motorola installation information. Set the Window Size
parameter in the repeater to 5 or 6, depending on the setting for Privacy Type. See Enhanced GPS Radio Update
Tables on Pages 27 and 28. This parameter must match the Window Size parameter in the Subscriber radios.
Step 2. for MOTOTRBO
Connect RadioPro IP Gateway to Control Station Radio
Note: Before continuing, ensure that the programming cable has been disconnected from the front mic connector.
Connect the IP Gateway to the Control Station Voice radio using the following steps:
1. Connect the USB connector of cable S2-61431 to any USB port on the rear of the RadioPro IP Gateway module. In
addition, for this Voice Control Station radio, connect the DE-9 side of cable S2-61431 to the DE-9 connector on the
rear of the RadioPro IP Gateway module.
2. Connect the other end of the cable to the Rear Accessory Connector on the MOTOTRBO Voice radio.
Connect the RadioPro IP Gateway to the Data Revert Control Station radios using the following steps:
3. Connect the USB connector of cable S2-61664 to any USB port on the rear of the RadioPro IP Gateway module.
4. Connect the other end of the cable to the Rear Accessory Connector on the MOTOTRBO Data radio.
Since the IP Gateway has not been configured yet with appropriate IP parameters, do NOT connect the IP Gateway to an
IP network.