Step 1b. for MOTOTRBO
Configure MOTOTRBO Connect Plus Option Board
If this Control Station radio is being used in a Connect Plus system, then the Connect Plus Option Board must also be
configured. Use Connect Plus Option Board CPS version R01.30.100 (or later) to configure the Option Board using the
following steps. (CTI Cable S2-61431 may be used as a programming cable in lieu of the Motorola programming cable.)
1. Menu folder:
a. In the “Contacts” section, enable
Call Alert, Manual Dial, Radio
Check, Remote Monitor,
Radio Enable, and Radio
Disable.
b. In the “Call Log” section, enable
Missed, Answered, and
Outgoing.
2. Write the CPS parameters to the Connect
Plus Option Board. CTI Cable S2-61431
may be used as a programming cable in lieu
of the Motorola programming cable.
3. Remove the programming cable from the
Control Station radio. A programming cable
connected to the front mic connector on the
Control Station radio will prevent
communications to a RadioPro IP Gateway from the Rear Accessory Connector. Therefore, when a cable is
connected to the Rear Accessory Connector to connect a RadioPro IP Gateway or a PC (during programming), ensure
that the programming cable has been disconnected from the front mic connector.