8. Writing CPS Parameters to Radio:
After writing the CPS parameters to the MOTOTRBO Control Station radio, remove the programming cable from
the Control Station radio. A programming cable connected to the front mic connector on the Control Station radio
will prevent communications to a RadioPro IP Gateway from the Rear Accessory Connector. Therefore, when a
cable is connected to the Rear Accessory Connector to connect a RadioPro IP Gateway or a PC (during
programming), ensure that the programming cable has been disconnected from the front mic connector.
Summary of MOTOTRBO CPS Setup for Control Station Radios
Folder Sub-Folder Parameter Step # Setting
General
Settings
Main Radio ID 2a.
Voice Radio and Data Revert Radio that share an IP
Gateway must have the same Radio ID
Main GPS 2b. Disable
Microphone Analog Mic AGC 2c. Disable
Microphone Digital Mic AGC 2c. Disable
Persistent LRRP
Save 2d. Disable
Persistent LRRP
Delete 2d. Disable
Accessories
Main Ignition Sense 3a. On/Off Or Ignition
Main
Analog Rear Mic
Gain
3b.
+ 10dB: May need to be adjusted for appropriate
audio level transmitted from RadioPro client
Main
Digital Rear Mic
Gain
3c.
+ 10dB: May need to be adjusted for appropriate
audio level transmitted from RadioPro client
Main Cable Type 3d. Rear PC and Audio
Network
Main Radio IP 4a.
For radios sharing an IP Gateway, the IP address of
the Voice Radio must be lower than the IP
addresses of the Data Revert Radios.
An IP Gateway and all radios connected to it must
have unique subnets.
Radio Network Forward to PC 4b. Via USB
Services ARS Radio ID 4c. Leave this field blank
Services TMS Radio ID 4c. Leave this field blank
Signaling
Systems
MDC, Digital, or
Capacity Plus
System 5a.
Choose appropriate parameters for the signaling
system being added for All-Emergency function
Contacts
MDC, Digital, or
Capacity Plus
add Group Call 6a. Add Group Call contact for the Group Call function
add All Call 6b. Add All-Call contact for the All-Call function
Channels
Digital ARS 7a. Disable for all channels
Digital
Compressed UDP
Data Header
7b Enable for all channels
Digital
or Analog
Emergency System 7c
Choose appropriate Emergency ID for All-
Emergency function
Digital Data Call Confirmed 7d. Disable for all channels
Connect Plus Option Board 7e. Enable for all Connect Plus talk groups