Manual

CIB Hardware Reference Connectors
CTI Products, Inc.
68-10854-135
12
Signal Direction Description
VOTE Input/Output Output activated to force vote a receiver.
Comparator grounds input to indicate a voted receiver.
RX Input Ground to indicate that a signal is being received.
DIS Input/Output Output activated to disable a receiver.
Ground input to indicate a disabled receiver.
FAIL Input Ground input to indicate a failed receiver.
MON Output Activated to force vote a receiver in the TAC and Ericsson /
G.E. comparators. Unused for all other comparators.
Table 8 - I/O Signal Descriptions