Manual
CHIB Hardware Reference Option Switches
CTI Products, Inc.
68-11662-100
5
4. Option Switches
Five sets of option switches are provided for module configuration.
4.1 Front Panel Switches
The front panel switch functions are shown below:
SWITCH MODULE DESCRIPTION DEFAULT
OPTION A
position 1 Vote Hold Time 1 Sec UP
position 2 Vote Hold Time 2 Sec UP
position 3 Vote Hold Time 4 Sec UP
position 4 Vote Hold Time 8 Sec UP
position 5 Vote Hold Time 16 Sec DOWN
position 6 Vote Hold Time 32 Sec DOWN
position 7 Not Connected DOWN
position 8 Not Connected DOWN
Table 2 - CHIB Front Panel Option A Switches
The Vote Hold Time is the sum of all the Active (Up) Vote Hold Time switches.
Default is 15 seconds. Setting all switches Down will disable Vote Hold.
The Vote Hold Time switches are read in real-time and will take effect on the next
active Vote signal.