Operation Manual

6  •  GB
PARAMETERS
PROGRAM DESCRIPTION
Current (Amperes)
Voltage (Volts)
Desulphation Soft Start Bulk Absorption
Recovers a  
sulphated battery
Tests the battery
condition
Bulk charge
Peak charge with
minimal uid loss
MULTI XS 25000
MODE Desulphation Soft Start Bulk Absorption
NORMAL 
or 
RECOND
YES Max 25A for 4h until the 
voltage reaches 12.6V.
25A for max 20h. 14.4V until   after the 
current dropped to 4.5A, 
max 12h.
SUPPLY
XS 25000
MODE Desulphation Soft Start Bulk Absorption
PRESET YES Max 25A for 4h until the 
voltage reaches 12.6V.
25A for max 20h. 14.4V until 4h after the 
current dropped to 4.5A, 
max 12h.
MULTI XT 14000
MODE Desulphation Soft Start Bulk Absorption
NORMAL 
or 
RECOND
YES Max 14A for 4h until the 
voltage reaches 25.2V.
14A for max 20h. 28.8V until 4h after the 
current dropped to 2.5A, 
max 12h.
SUPPLY
XT 14000
MODE Desulphation Soft Start Bulk Absorption
PRESET YES Max 14A for 4h until the 
voltage reaches 25.2V.
14A for max 20h. 28.8V until 4h after the 
current dropped to 2.5A, 
max 12h.