User manual
Chapter 5. Configure via Console Port
5-22
For configuring e_bit, move the cursor to e_bit and press [ENTER]. Select
the parameter via [TAB] key.
-----------------------------------------------------------
code Configure e1 code
frame Configure e1 frame
rai Configure e1 rai
build_outs Configure e1 build outs
>> e_bit Configure e1 e_bit
------------------------------------------------------------
Command: setup e1 e_bit <enable|disable>
Message: Please input the following information.
SHDSL E1 e_bit (TAB Select) <disable>: enable
------------------------------------------------------------
Restore factory default
If you want to restore factory default setting in setup, select default
and press [ENTER] or [RIGHT].
----------------------------------------------------------
type Configure shdsl type
shdsl Configure shdsl parameters
e1 Setup e1 parameters
>> default Restore factory default setting
------------------------------------------------------------
Command: setup default
Message: Please input the following information.
Are you sure? (y/n): y
---------------------------------------------------------------
If you enter “y” the setup field will be automatically configured to factory