Setup Serial Parameter, Data Rate
For 2-wires with Annex A and B, the rate can be adjusted in increments of 64kbps from 64kbps to 2304kbps (N=1~36).
For 2-wires with Annex F and G, the rate can be adjusted in increments of 64kbps from 192kbps to 5696kbps (N=3~89).
For 4-wires with Annex A and B, the rate can be adjusted in increments of 64kbps from 128kbps to 4608kbps (N=2~72 , even
number only).
For 4-wires with Annex F and G, the rate can be adjusted in increments of 64kbps from 384kbps to 8192kbps
(N=6~128, even number only ).
Setup Serial Parameter, Clock Polarity
The data port clock polarity may be adjusted to solve some rare clocking issues. The default setting is 'Normal' clock polarity,
where data is sent on the negative transition of the clock, while the option exists to set inverse clock polarity where data is sent
on the positive clock transition.