Product specifications
Table Of Contents

Chapter 3 Configuration and Operation
19
3.10.3 CPE Unit Factory Default Script
CPE default, replace xx:xx:xx with CO unit's unique MAC address
gci
srcnet 172.16.1.2 255.255.255.0
ipset 192.168.2.11 255.255.255.0 172.16.1.1
ceschset 1 1 172.16.1.1 00:02:AB:xx:xx:xx
ceschset 2 1 172.16.1.1 00:02:AB:xx:xx:xx
ceschset 3 1 172.16.1.1 00:02:AB:xx:xx:xx
ceschset 4 1 172.16.1.1 00:02:AB:xx:xx:xx
cespwidset 1 1 1
cespwidset 2 2 2
cespwidset 3 3 3
cespwidset 4 4 4
pktsize 1 0
pktsize 2 0
pktsize 3 0
pktsize 4 0
jitterbd 1 1
jitterbd 2 1
jitterbd 3 1
jitterbd 4 1
ceschclkset 1 0
ceschclkset 2 0
ceschclkset 3 0
ceschclkset 4 0
lanset 1 7
csave
The factory default scripts allow the units to connect with 4xE1 over any LAN environment. To quickly
modify these two scripts for your LAN:
1. Change the ‘srcnet’ IP address to the new IP you want for the WAN port.
2. Change the ‘ipset’ to the IP, Subnet and GW for the MNT (management) port.
3. Change the ‘ceschset’ IP address to be the WAN destination for the PW (the opposite IPM)
4. Make sure the ‘ceschset’ MAC address is the actual MAC address of the destination unit (opposite
IPM).