A.3.1 Web Management
Eoe1 “E1 Port” tab contains the status and E1 parameter settings. The status fields will report Signal normal or
LOS, E1 sync or NoSync, Alarm Indication Signal active or not, Bit errors if running integral BERT, code violations,
Loss of Multi-Frame and remote power condition (dying gasp).
The E1 configurations include enabling the device for transmission, selecting HDB3 or AMI line coding, E1
timing of recovery, internal, from DTE or transparent, E1 impedance of 75 ohm (for BNC) or 120 ohm (for RJ45),
E1 idle code selectable between the default 0x7E or optional 0xFF, framed or unframed mode, if framed the
settings can be CCS (PCM31) or CAS (PCM30). The E1 loop back tests can be initiated along with Bit Error Rate
Testing. Finally, the randomly assigned timeslots can be check off.
The “LAN Port” tab has the status
and configuration settings for the single
RJ-45 LAN port. The link status and
speed/duplex will be shown (if linked).
The two configuration items include auto
or forced mode (10/100, full/half)
selection and enable/disable 802.3x
Ethernet flow control.
The “RMON” tab provides status
and enable/disable of the RMON
counter function. The counter records
the number of packets received and
transmitted by the LAN port. Additional
button controls allow refreshing or
clearing the counters.