Specifications

Appendix A
Specifications
G.703 Interface
Connector HDB26 Female with adapters for 75 or 120 Ohm
Data rate 2048kb/s
Impedance 75 ohm for unbalanced, 120 ohm for balanced
Framing Requires Unframed, transparent clear channel E1s
RxSensitivity -43dB (extra Long Haul)
TxPulseAmp. 3.00V p-p (120 ohm); 2.73V p-p (75 ohm)
Line code HDB3
Indications LED (PWR, Alarm, Individual E1 status, Link, SD)
Ethernet Port 1 x RJ-45, Auto-Negotiation, Auto-MDIX (T-model)
1 x caged SFP (100Base-FX) (S-model)
VLAN IEEE802.1Q tagged VLAN support
Maximum MTU 1916 bytes
Ingress/Egress Bandwidth control (32K to 100M, nx32K granularity)
GFP-F per ITU-T G.7041
LCAS Enabled or disabled
Power (Card supports hot-swapping)
Input Card : 12VDC, Standalone : AC, DC options
Consumption <6W
Dimensions 155 x 88 x 23mm (D x W x H)
Weight 120g
Temperature 0 ~ 50°C (Operating), -10 ~ 70°C (Storage)
Humidity 10 ~ 90% non-condensing
Certification CE, FCC, LVD, RoHS
MTBF 65000 hrs (25°C)
Test Loops (set from console)
E1 Remote and Request Remote Loop back
BERT Integral 511 pattern generator (set from console)
This product includes the following models:
FRM220A-5, 8, 16E1-ET100T (5E1, 8E1 or 16E1 with RJ-45 LAN)
FRM220A-5, 8, 16E1-ET100S (5E1, 8E1 or 16E1 with SFP LAN)
A.1.1 Web Management
The “E1 Port” tab is mostly informational. For each of the E1 lines we can observe if there is normal signal,
sync, AIS alarm, RAI, Loss of Multi-Frame and whether the port is active or not.
Loop back for any of the E1 circuits can also be enabled here. The loop back can be used in conjunction with
the integral BERT to confirm link integrity.