Specifications
Chapter 2 Provisioning
19
For an example of configuration for Alarm #2, press '2' (two).
Set Alarm 2 Mode.
<0> Disable <1> By Fan <2> By Define 1 <3> By Define 2
<ESC>:Previous Menu.
0 : This will completely disable Alarm #2.
1 : This is the factory default setting. This alarm will only be off when two fan modules are installed and working normally.
2 : This setting will take the user parameters and set the alarm according to failures in parameters set under items 1.
3 : This setting will take the user parameters and set the alarm according to failures in parameters set under items 2.
User Alarm Definitions
<< User Define 1 Configuration >>
Chassis:
<1> :[ ]Power 1 Status
<2> :[ ]Power 2 Status
<3> :[ ]Fan 1 Status
<4> :[ ]Fan 2 Status
Local:
<5> :[ ]UTP Link Status
<6> :[ ]FX Link Status
<7> :[ ]FEF Detected
<8> :[ ]Remote Power Status
Remote:
<9> :[ ]UTP Link Status
<A> :[ ]FX Link Status
<ESC>:Go to Previous Menu.
When alarm mode is set to "User", these definitions may be added to either User#1 or User#2. Any selected
item that fails will cause alarm activation (and SNMP trap if SNMP is enabled). For chassis activated alarms, the
user may select individual power or fan combinations. For locally generated alarms, any copper, fiber, Far End
Fault or Remote Power Failure can be selected (or as supported), in any combination to generate an alarm on
failure from installed cards. For any remotely connected in-band converters, any copper, fiber, or Far End Fault
may be used to trigger the alarm relay (only for OAM managed converters).
Below is an example of user settings where Alarm#1 will be triggered if any local copper or fiber link, Far End
Fault or remote power has failure. The system is designed to allow very flexible use of the two alarms through
customized monitoring schemes.
<< User Define 1 Configuration >>
Chassis:
<1> :[ ]Power 1 Status
<2> :[ ]Power 2 Status
<3> :[ ]Fan 1 Status
<4> :[ ]Fan 2 Status
Local:
<5> :[*]UTP Link Status
<6> :[*]FX Link Status
<7> :[*]FEF Detected
<8> :[*]Remote Power Status
Remote:
<9> :[ ]UTP Link Status
<A> :[ ]FX Link Status
<ESC>:Go to Previous Menu.