Specifications

Appendix A
82
Switch 3 settings
After setting the required nx64k timeslot amount, set the starting timeslot number for the contiguous set of
active timeslots.
Do not use TS16 if E1-CAS is used
For T1 there are no timeslots above TS24
DIP SW3
SW STATE Function
1 2 3 4 5 First timeslot
OFF OFF OFF OFF OFF Full E1/T1
ON OFF OFF OFF OFF Timeslot 1
OFF ON OFF OFF OFF Timeslot 2
ON ON OFF OFF OFF Timeslot 3
OFF OFF ON OFF OFF Timeslot 4
ON OFF ON OFF OFF Timeslot 5
OFF ON ON OFF OFF Timeslot 6
ON ON ON OFF OFF Timeslot 7
OFF OFF OFF ON OFF Timeslot 8
ON OFF OFF ON OFF Timeslot 9
OFF ON OFF ON OFF Timeslot 10
ON ON OFF ON OFF Timeslot 11
OFF OFF ON ON OFF Timeslot 12
ON OFF ON ON OFF Timeslot 13
OFF ON ON ON OFF Timeslot 14
ON ON ON ON OFF Timeslot 15
OFF OFF OFF OFF ON Timeslot 16 (E1 CAS Don’t use)
ON OFF OFF OFF ON Timeslot 17
OFF ON OFF OFF ON Timeslot 18
ON ON OFF OFF ON Timeslot 19
OFF OFF ON OFF ON Timeslot 20
ON OFF ON OFF ON Timeslot 21
OFF ON ON OFF ON Timeslot 22
ON ON ON OFF ON Timeslot 23
OFF OFF OFF ON ON Timeslot 24
ON OFF OFF ON ON Timeslot 25 (T1 TS25~31 Don’t use)
OFF ON OFF ON ON Timeslot 26
ON ON OFF ON ON Timeslot 27
OFF OFF ON ON ON Timeslot 28
ON OFF ON ON ON Timeslot 29
OFF ON ON ON ON Timeslot 30
1,2,3,4,5
ON ON ON ON ON Timeslot 31
6,7 Reserved
OFF
6,7
ON
8 Loop Back Group Setting
OFF Fiber Side
8
ON E1/T1 Side