Specifications

Appendix A
81
Switch 2 settings
Use the switches 1~5 to set the nx64k rate
For T1, the maximum is 24 timeslots
For E1-CCS the maximum is 31 timeslots
For E1-CAS the maximum is 30 timeslots
DIP SW2
SW STATE Function
1 2 3 4 5 Fraction timeslot number setting
OFF OFF OFF OFF OFF Full E1/T1
ON OFF OFF OFF OFF 1 timeslot
OFF ON OFF OFF OFF 2 timeslots
ON ON OFF OFF OFF 3 timeslots
OFF OFF ON OFF OFF 4 timeslots
ON OFF ON OFF OFF 5 timeslots
OFF ON ON OFF OFF 6 timeslots
ON ON ON OFF OFF 7 timeslots
OFF OFF OFF ON OFF 8 timeslots
ON OFF OFF ON OFF 9 timeslots
OFF ON OFF ON OFF 10 timeslots
ON ON OFF ON OFF 11 timeslots
OFF OFF ON ON OFF 12 timeslots
ON OFF ON ON OFF 13 timeslots
OFF ON ON ON OFF 14 timeslots
ON ON ON ON OFF 15 timeslots
OFF OFF OFF OFF ON 16 timeslots
ON OFF OFF OFF ON 17 timeslots
OFF ON OFF OFF ON 18 timeslots
ON ON OFF OFF ON 19 timeslots
OFF OFF ON OFF ON 20 timeslots
ON OFF ON OFF ON 21 timeslots
OFF ON ON OFF ON 22 timeslots
ON ON ON OFF ON 23 timeslots
OFF OFF OFF ON ON 24 timeslots
ON OFF OFF ON ON 25 timeslots
OFF ON OFF ON ON 26 timeslots
ON ON OFF ON ON 27 timeslots
OFF OFF ON ON ON 28 timeslots
ON OFF ON ON ON 29 timeslots
OFF ON ON ON ON 30 timeslots
1,2,3,4,5
ON ON ON ON ON 31 timeslots
6 Auto laser shutdown setting
OFF Disable
6
ON Enable
7 Unused timeslot idle code setting
OFF 0x7E
7
ON 0xFF
8 8 Reserve