A.5.3 Factory Reset Procedure
Apply power to the 1000EAS and allow 30 seconds to fully boot. Using a pencil or ball-point pen, press the
'DEFAULT' recessed push-button switch (located on the face plate) and hold for 9~10 seconds. DO NOT POWER
OFF. Allow the unit to again fully reboot. The defaults are:
IP=10.1.1.1
netmask=255.0.0.0
GW=10.1.1.254
TFTP server=10.1.1.100
The username and password are both reset to 'admin' if enabled.
A.5.3.1 Installation of SFP Modules
CTC Union supplied SFP modules are of the Bale Clasp type. The bale clasp pluggable module has a bale
clasp that secures the module into the SFP cage.
A.5.3.2 Inserting a Bale Clasp SFP Module into the Cage
Step 1 Close the bale clasp upward before inserting the pluggable module.
Step 2 Line up the SFP module with the port, and slide it into the cage.
A.5.3.3 Removing a Bale Clasp SFP Module
Step 1 Open the bale clasp on the SFP module. Press the clasp downward with your index finger.
Step 2 Grasp the SFP module between your thumb and index finger and carefully remove it from the SFP cage.
Figure A.5.2 Bale Clasp type SFP with bale open
A.5.4 Provisioning
Because of the complex settings of 1000EAS and because there exists a stand-alone user manual for the 1000EAS, this NMC
user manual will not go into the detailed settings here.
Please refer to the FRM220-1000EAS User Manual.