Specifications
Appendix A 
63 
A.4.1 Specifications 
 Optical Interface 
  Connector  SFP cage (depending on model) 
  Optical rate  125Mb/s 
  Duplex mode  Full duplex 
  Fiber  MM 50/125um, 62.5/125um 
    SM 9/125um (depending on SFP) 
  Distance  MM 550M/2KM, 
    SM 15/30/50/80/120KM (depending on SFP) 
  Wavelength  Depends on SFP and model 
 Electrical Interface 
  Connector  RJ-45 x 2 
  Data Rates  10Mbps, 100Mbps 
  Duplex  Full or Half Duplex 
  Cable  10Base-T Cat. 3,4,5,5e UTP 
     100Base-TX Cat. 5, 5e or higher 
 Standards  IEEE802.3, 802.3u, 802.3ah, 802.3x 
    802.1D, 802.1p, 802.1Q, 802.1ad, RFC 4330 (SNTP) 
 Maximum MTU  1536 bytes 
 Indications  LED (PWR, Fiber 1&2 Link, Test, UTP 3&4 Link, UTP 3&4 Speed) 
 Power  (Card supports hot-swapping) 
  Input  Card : 12VDC, Standalone : AC, DC options 
  Consumption  <8W 
 Dimensions  155 x 88 x 23mm (D x W x H) 
 Weight  120g 
 Temperature  0 ~ 50°C (Operating), -10 ~ 70°C (Storage) 
 Humidity  10 ~ 90% non-condensing 
 Certification  CE (EMC/LVD), FCC, RoHS 
 MTBF  7
5000 hrs (25°C) 
A.4.2 Management Features 
The  FRM220-10/100AS-2 has its own embedded processor which can be used to configure the device for 
stand-alone operation. When placed in a stand-alone chassis, this device supports a text based Telnet terminal 
with an easy to use menu system for configuration. The embedded HTTP server provides an easy to use GUI 
(Graphical User Interface) with any web browser. SNMP is also supported in the stand-alone operation. When 
using network management software and our proprietary MIB file specifically for the 100A,  all settings can be 
performed, performance monitoring realized and alarm traps received. When placed in a managed chassis, such 
as our FRM220-CH20 with NMC (Network Management Controller) card, the 10/100A card is configured and 
monitored through the chassis NMC via console, Telnet, Web HTTP or SNMP. 
1. Stand-alone – IP settings allow management by Telnet, Web or SNMP 
2. Rack management - When placed in NMC managed rack, all other settings can be overridden by the NMC management. 
A.4.3 Factory Reset Procedure 
Apply power to the 10/100A and allow 30 seconds to fully boot. Using a pencil or ball-point pen, press the 
'DEFAULT' recessed push-button switch (located on the face plate) and hold for 9~10 seconds. DO NOT POWER 
OFF. Allow the unit to again fully reboot. The defaults are: 
IP=10.1.1.1 
netmask=255.0.0.0 
GW=10.1.1.254 
TFTP server=10.1.1.200 
(The username and password are both reset to 'admin' if enabled.) 










