Specifications

Appendix A
63
A.4.1 Specifications
Optical Interface
Connector SFP cage (depending on model)
Optical rate 125Mb/s
Duplex mode Full duplex
Fiber MM 50/125um, 62.5/125um
SM 9/125um (depending on SFP)
Distance MM 550M/2KM,
SM 15/30/50/80/120KM (depending on SFP)
Wavelength Depends on SFP and model
Electrical Interface
Connector RJ-45 x 2
Data Rates 10Mbps, 100Mbps
Duplex Full or Half Duplex
Cable 10Base-T Cat. 3,4,5,5e UTP
100Base-TX Cat. 5, 5e or higher
Standards IEEE802.3, 802.3u, 802.3ah, 802.3x
802.1D, 802.1p, 802.1Q, 802.1ad, RFC 4330 (SNTP)
Maximum MTU 1536 bytes
Indications LED (PWR, Fiber 1&2 Link, Test, UTP 3&4 Link, UTP 3&4 Speed)
Power (Card supports hot-swapping)
Input Card : 12VDC, Standalone : AC, DC options
Consumption <8W
Dimensions 155 x 88 x 23mm (D x W x H)
Weight 120g
Temperature 0 ~ 50°C (Operating), -10 ~ 70°C (Storage)
Humidity 10 ~ 90% non-condensing
Certification CE (EMC/LVD), FCC, RoHS
MTBF 7
5000 hrs (25°C)
A.4.2 Management Features
The FRM220-10/100AS-2 has its own embedded processor which can be used to configure the device for
stand-alone operation. When placed in a stand-alone chassis, this device supports a text based Telnet terminal
with an easy to use menu system for configuration. The embedded HTTP server provides an easy to use GUI
(Graphical User Interface) with any web browser. SNMP is also supported in the stand-alone operation. When
using network management software and our proprietary MIB file specifically for the 100A, all settings can be
performed, performance monitoring realized and alarm traps received. When placed in a managed chassis, such
as our FRM220-CH20 with NMC (Network Management Controller) card, the 10/100A card is configured and
monitored through the chassis NMC via console, Telnet, Web HTTP or SNMP.
1. Stand-alone – IP settings allow management by Telnet, Web or SNMP
2. Rack management - When placed in NMC managed rack, all other settings can be overridden by the NMC management.
A.4.3 Factory Reset Procedure
Apply power to the 10/100A and allow 30 seconds to fully boot. Using a pencil or ball-point pen, press the
'DEFAULT' recessed push-button switch (located on the face plate) and hold for 9~10 seconds. DO NOT POWER
OFF. Allow the unit to again fully reboot. The defaults are:
IP=10.1.1.1
netmask=255.0.0.0
GW=10.1.1.254
TFTP server=10.1.1.200
(The username and password are both reset to 'admin' if enabled.)