Specifications

Chapter 3 Web Based Management
36
Alarm 1 & 2 Settings
Alarm 1 Mode can choose Disabled, By Powers, By User 1 or Active from the drop-down menu. If disabled, no
condition will cause the Alarm 1 relay to close or become active.
When selecting the "By Powers" option, the Alarm 1 relay will be closed on any single power failure. The "By
User 1" option is used in conjunction with the "Chassis", "Local" and "Remote" User check boxes. User setting
allows configuring custom alarm conditions. These alarm settings are also used to send SNMP traps. Therefore,
the settings are not only important for the alarm relays but also for SNMP management as well.
The "Active" setting will close the Alarm 1 relay for testing purposes. Set it back to any other mode after test.
Alarm 2 Mode can choose Disabled, By Fans, By User 2 or Active from the drop-down menu. If disabled, no
condition will cause the Alarm 2 relay to close or become active.
When selecting the "By Fans" option, the Alarm 2 relay will be closed on any single fan failure. The "By User 2"
option gives any user selectable fault option to be assigned to the Alarm 2 relay. The "Active" setting will close the
Alarm 2 relay for testing purposes. Set it back to any other mode after test.
Note: The UTP remote UTP and Fiber link status monitoring and Remote Power Fail (dying gasp) only apply to
OAM cards. (10/100i, 10/100A, 1000EAS). Signal loss only applies to the E1/T1 card. Remote power failure only
works with in-band cards that support dying gasp.