Specifications

Chapter 3 Web Based Management
34
3.3.2.9 SNMP + Chassis
Click on "SNMP+Chassis" from the left hand window menu bar.
Header
The top header displays the chassis ID (0 for the master chassis, 1~9 for cascaded slave chassis), the slot
number for NMC is always 1, NMC is always in local and the version displayed in the format h/w-s/w. In the above
example, the NMC hardware version is 1.0 while the software version is 3.263 and kernel build 14622.
Chassis Information
The Chassis Information group displays the power supply types and the power and fan status. There are slots
for installing one or two power modules. They may hold either AC or DC type modules. Power 1 refers to the
module installed in the left slot as viewed from the rear of the chassis, while Power 2 refers to the right slot. An OK
status indicates the power module is working within normal parameters. Fan status is indicated with both the
current RPM (speed) of the cooling fans and with a status of OK or Failed. If the RPM of the fan falls below
1650RPM, a failed status will be indicated.