A.14.6 Firmware Upgrade
1. From the "System" menu click the "Upgrade Line Card" button.
2. Select the card type radio button, which in this case is the FRM220-10G-SS
3. Select the slot to update. Selecting "All Slots" will upgrade all local 10G-SS cards. (this may take up to 15 minutes)
4. If selecting an individual slot, you must also select either the local unit. (remote not supported in this model)
5. The image file name needs to be keyed in. The TFTP server should be able to find this file and the "System" settings need to
be correct (see Chapter 2, settings). There are two image files for the 10G-SS, one is the firmware, the other is the CDR code
.
Upgrade the firmware first and then upgrade the CDR if required.
6. Click the "Upgrade" button to start the update.