User manual
Chapter 2. Installation 
2.5 Electrical Installation 
2.5.1 Power connection, AC 
For a model with AC power supply, AC power (100~240VAC) is supplied to the FMUX04 
through a becoming standard clover leaf 3-prong receptacle, located on the rear of the unit. 
The  FMUX04 should always be grounded through the protective earth lead of the power 
cable in AC installations. 
AC Input 
2.5.2 Power connection, DC 
For a model with DC power supply, DC -24V (18~36VDC) or DC -48V (36~72VDC) is 
connected to the detachable terminal block. The DC power connector uses a 'Molex' type 
connector with detachable terminal block. Please take extra caution to observe the proper 
polarity of the DC when wiring the connector. The FMUX04 should always be grounded 
through the protective earth lead via the frame ground connection for DC installations. 
DC Input 
18~36VDC  36~72VDC 
Figure 2-3 : Supply connections, AC/DC models shown 
19 