User manual

Chapter 2. Port Card Overview
2-6 FMUX-01Mar 2003
When the MULTIPLEXER UNIT is ordered with an RS232 Port Card option, a 4-
CHANNEL RS-232 Card and adapter cable are supplied with each DB25 wired according
to the following table.
Signal
Function
DB25
PIN
Circuit Direction Description
Protective
Ground
1 AA ?
Chassis ground.
May be isolated from signal ground.
Signal
Ground
7 AB ? Common signal ground.
Transmitted
Data
2 BA To MUX UNIT
Serial digital data from DTE.
Received
Data
3 BB Fm MUX UNIT
Serial digital data at the output of the
MULTIPLEXER
UNIT receiver.
Request to
Sent
4 CA To MUX UNIT
A ON signal to the MULTIPLEXER UNIT when data
transmission is desired.
Clear to
Sent
5 CB Fm MUX UNIT
Constantly ON.
Data Set
Ready
6 CC Fm MUX UNIT
Constantly ON,
Except during test loops.
Data Terminal
Ready
20 CD To MUX UNIT
DTR not used, used for a received serial data rate
clock input from the DTE.
Data Carrier
Detect
8 CF Fm MUX UNIT
Constantly ON, except when a loss of the received
carrier signal is detected.
External Transmit
Clock
24 DA To MUX UNIT
A transmitted data rate clock input from the data
source.
Transmit
Clock
15 DB Fm MUX UNIT
A transmitted data rate clock for use by an external
data source.
Receive
Clock
17 DD Fm MUX UNIT
A received data rate clock for use by an external data
source.
Remote
Loop back
21 RL To MUX UNIT
When on, commands MULTIPLEXER UNIT into
remote loop back.
Local
Loop back
18 LL To MUX UNIT
When on, commands MULTIPLEXER UNIT
into local
loop back.
Test Indicator 25 TM Fm MUX UNIT
ON during any test mode
Table 2-5 : DB25 adapter cable pin out for RS-232