User manual

Chapter 1. Introduction 
1-6  Multiplexer Unit : Apr 2003 
LED Indicators 
Power 1 
Green  Power Module 1 active 
Power 2  Green  Power Module 2 active 
Optical 1  RED  Off = off 
On = working (ALS is off) 
On = working & linked (ALS is set Auto) 
Blinking = working & not linked 
(If ALS is disabled, then the not linked condition will 
not be indicated by a blinking LED) 
Optical 2  RED  Off = disabled 
On = standby (ALS is off) 
On = standby & linked (ALS is set Auto) 
Blinking = Standby & not linked 
(If ALS is disabled, then the not linked condition will 
not be indicated by a blinking LED) 
Channels  GREEN  One LED for each channel (A-D) of each Port (1-4) 
or a total of 16 LED. 
On = In Service 
Off = Out of Service 
Blinking = Loss of Signal 
Audible Alarm
 Cutoff 
Amber  Audible Alarm has sounded, alarm cutoff switch has 
been pushed 
Minor Alarm  Amber  Indicates a minor alarm has occurred
, includes E1 or 
T1 BPV or fiber sync slip. 
Major Alarm  RED  Indicates a major alarm has occurred, includes E1, 
T1, and fiber signal loss. 
Far End Error  Amber  Indicates a far end (remote) error has occurred 
Near End Error
RED  Indicates a near end (local) error has occurred 
System Failure
RED  Indicates a failure in the "system" such as fiber LOS 
Optical  (Dual)  GREEN = optical link established 
RED = optical link failure 
E1  (Dual)  GREEN = E1 active, no errors 
RED = E1 Signal Loss 
Off = No E1 
T1  (Dual)  GREEN = T1 active, no errors 
RED = T1 Signal Loss 
Off = No T1 
RS-232 Console Port 
Port interface  V.24/RS-232 asynchronous, DCE 
Port connector  RJ-45 
Data rate (*default)  19200 bps 
Data format  -One start bit 
-8 data bits 
-No parity 
-One stop bit 
RJ-45 Pin Usage 
RJ-45(DCE) DB9(DTE) 
 4 GND 5 
 5 TD  2 
 6 RD 3 