User manual

Chapter 1. Introduction 
1-5  Multiplexer Unit : Apr 2003 
Data Port Channels 
Interface Types  V.35 
X.21 
RS-530/V.36 
RS-449 
RS-232 
Interface Connectors 
V.35 Interface 
X.21 Interface 
RS-530 Interface 
RS-449 Interface 
RS-232 Interface 
(provided by adapter cables) 
34 pin, Female or Male 
15 pin, D-type Female or Male 
25 pin, D-type Female or Male 
37 pin, D-type Female or Male 
25 pin, D-type Female or Male 
Line Code  NRZ 
Data Rate (each channel)  n?64Kbps (64 ~ 2048Kbps) 
where n equal 1 to 32 
RS-232 maximum is 128Kbps 
Clock Modes  Transparent, recovery, External, or Internal 
Control Signals  CTS constantly ON or follows RTS 
DSR constantly ON, except during test loops 
DCD constantly ON, except during signal loss 
Test Loops  LLB (Local Loop Back) 
RLB (Remote Loop Back) 
V.54 
Bridge Port Channels 
Interface Type  10Base-T, 100Base-TX (auto-negotiation) 
Interface Connector  RJ-45 
WAN Data Rate   2048Kbps (to 8192Kbps depending on version) 
Complies with  IEEE802.3 10Base-T 
IEEE802.3u 100Base-TX 
Test Loops  NONE 
Local Setup and Configuration 
LCD  2 rows of 16 characters 
Pushbutton Switches  ESC 
Left Arrow (-) 
Right Arrow (+) 
Enter 
Alarm Output Relays 
Alarm Output  Four pairs of Normally Open contacts for Major 
and Minor alarms, both audio and visual. 
Contact ratings: 1A at 30 VDC resistive 
 or 0.5A at 125 VAC resistive 
Pin Assignment (DB9F)  1 - 2 / Major (audio) 
3 - 4 / Major (visual) 
5 / frame ground 
6 - 7 / Minor (audio) 
8 - 9 / Minor (visual) 