User manual
Chapter 4. Operation
37 Version 1.2 Apr 2006
If we <ESC> back to the "Define System" menu we can configure the card in Port 2 by
pressing "4". This is an example for the T1 4-channel module (balanced 100 Ohm)
LOCAL <<< Define Port 2 Parameter >>>
Ch A Ch B Ch C Ch D
1. Service ON ON ON ON
2. Line Code B8ZS B8ZS B8ZS B8ZS
3. Loopback OFF OFF OFF OFF
Please Select Channel A ~ D or <ESC> to previous menu
The service status, Line Code setting, and Loopback mode are displayed for each of the 4
channels. To change any of the channel settings, select the individual channel with the
corresponding letter A~B~C~D or press <ESC> to exit this menu.
For an example of turning service off for Channel D, press "D".
LOCAL <<< Define Port 2 Parameter >>>
Ch A Ch B Ch C Ch D
1. Service ON ON ON ON
2. Line Code B8ZS B8ZS B8ZS B8ZS
3. Loopback OFF OFF OFF OFF
Please select Function 1 ~ 3 or <ESC> to previous menu.
Notice that "ch A" is highlighted, indicating it is the selected channel. To modify the service
status for the selected channel press "1"
LOCAL <<< Define Port 1 Parameter >>>
Ch A Ch B Ch C Ch D
1. Service ON ON ON ON
2. Line Code B8ZS B8ZS B8ZS B8ZS
3. Loopback OFF OFF OFF OFF
============================================================
[ Service ]
1. ON
2. OFF
Please select the item or <ESC> to previous menu.
Choose the desired loopback mode from the menu shown or press <ESC> to exit.