User manual

Chapter 4. Operation
27 Version 1.2 Apr 2006
4.1 Introduction
This chapter will go into the details of the specific configuration and operation of the Fiber
Multiplexer. Broken into two parts, the first part outlines the procedures and functions when using
the integral LCD display with push-button menu keys. The second section will outline the operation
when using a VT-100 terminal connected to the RS-232 Console port. For rapid and more complete
operation, a terminal connection to the Console port is recommended.
4.2 LCD Menu Operation
All controls (push-button switches), LCD display and LED indicators are located on the
Fiber Multiplexer front panel. The pushbutton switches are used to activate menu selections and
select parameter settings.
Use the '<' and '>' function keys to browse the menus and select parameters.
Use the 'Enter' function key to enter a sub-menu or to set a selected parameter.
Use the 'ESC' function key to return to a previous menu or to abandon setup.
When first powered on, the following "Administration" menu will be displayed. If a password
has been set, it must be entered to continue. The super user password is "1021" (no quotes).
Pressing ESC from this menu will briefly display the unit's firmware version number.
Pressing either ARROW key at this point will give the option to administer the remote site (as long
as there is a valid optical link). Pressing the ENTER key at this point will page the operator at the
top of the 10 top level Menus of either the local or selected remote unit. While administering the
local unit, the graphic menu arrows will appear as solid black (). While administering the
remote unit, the graphic menu arrows will appear as "less than" and "greater than" signs (< >).
A D M I N I S T R A T I O N
L O C A L S I T E
Initial LCD display. Press ENTER to configure the local unit and move to the top level Menus.
Pressing ESC from this menu will briefly display the unit's firmware version number.
A D M I N I S T R A T I O N
R E M O T E
S I T E
Pressing either Arrow key will provide access to the remote unit.
Press ENTER to configure the remote unit and move to the top level Menus.
4.2.0 Display Version Info From the Administration Local Site Menu or press ENTER to reach the
System Config menu.
S Y S T E M
C O N F I G
Pressing ESC at this menu will display the firmware and FPGA version numbers. (while
in local unit only)
F P G A V e r s i o n 5 . 1
F i r m w a r E V 2 . 0 3