Product specifications
Chapter 5 Operation
58
5.4.3 T1 (DS1) Interface Configuration
If the EOC (Embedded Operations Channel) connection is closed, a symbol "-" will be shown for each Re
(remote) configuration. (for example, if fiber link is down it will effect EOC)
[F2] Edit channel screen is shown below :
There are two T1 Line Codings : B8ZS or AMI
There are five LBO (Line Build Out) settings : 0-133ft / 133-266ft / 266-399ft / 399-533ft / 533-655ft .
4xT1 card modules supports unframed, clear channel T1 (DS1) only.
System Name: T1 Interface Parameters Config
[F3]Site: All [F4]SlotId: 2 [F5]ChId: All
+-----------------------------------------------------------------------------+
|[F1]St#/Sl#/Ch# Service Coding Framing T1/LBO Circuit Id |
|T1/Lo/2/1 IS B8ZS Unframed 0-133 ft |
|T1/Lo/2/2 IS B8ZS Unframed 0-133 ft |
|T1/Lo/2/3 IS B8ZS Unframed 0-133 ft #|
|T1/Lo/2/4 IS B8ZS Unframed 0-133 ft #|
|T1/Re/2/1 IS B8ZS Unframed 0-133 ft #|
|T1/Re/2/2 IS B8ZS Unframed 0-133 ft #|
|T1/Re/2/3 IS B8ZS Unframed 0-133 ft #|
|T1/Re/2/4 IS B8ZS Unframed 0-133 ft #|
| #|
| #|
| #|
| #|
| #|
+-----------------------------------------------------------------------------+
+-----------------------------------------------------------------------------+
| Edit[F2] Slot Edit[F6] Group IS[F7] Group OOS[F8] Back[ESC] |
+-----------------------------------------------------------------------------+
System Name: T1 Parameters Channel Editing
Location : Local/Slot 1/Ch 1
[F1] Circuit Identifier : __________________
[F3] Service Mode : IS
[F4] Frame Type : Unframed
[F5] Line Coding : B8ZS
[F6] LBO Setting : 0-133 ft
+-----------------------------------------------------------------------+
| Confirm[F2] Back[ESC] |
+-----------------------------------------------------------------------+