Product specifications
Chapter 5 Operation
54
5.4.1 E1 Interface Configuration
You can edit E1 Parameters for each channel or all channels of the selected slot.
[F6] Slot Edit- Edit the parameters of all channels in the same slot.
[F7]/ [F8]- You can just press [F7] or [F8] to let the selected channel in the screen go into the In-service
state or out of service
If the EOC connection is lost, a symbol "-" will be shown for each remote unit configuration.
If user uses "4xE1S" (Simple) E1 card, it does not support framing function (it is unframed ONLY).
System Name: E1 Interface Parameters Config
[F3]Site: All [F4]SlotId: 2 [F5]ChId: All
+-----------------------------------------------------------------------------+
|[F1]St#/Sl#/Ch# Service Coding Framing T1/LBO Circuit Id |
|E1/Lo/2/1 IS HDB3 Unframed |
|E1/Lo/2/2 IS HDB3 Unframed |
|E1/Lo/2/3 IS HDB3 Unframed #|
|E1/Lo/2/4 IS HDB3 Unframed #|
|E1/Re/2/1 IS HDB3 Unframed #|
|E1/Re/2/2 IS HDB3 Unframed #|
|E1/Re/2/3 IS HDB3 Unframed #|
|E1/Re/2/4 IS HDB3 Unframed #|
| #|
| #|
| #|
| #|
| #|
+-----------------------------------------------------------------------------+
+-----------------------------------------------------------------------------+
| Edit[F2] Slot Edit[F6] Group IS[F7] Group OOS[F8] Back[ESC] |
+-----------------------------------------------------------------------------+
[F3]: Select local, remote or both sites
by space bar, then press
the "Enter" key to select.
F5: Select which channel ID you wish to configure.
[F4]: Select 1~4 slots or all by space bar.