Product specifications

Chapter 4 Quick Start
17
4.1.4 Equipment Status
The screen is divided horizontally, displaying the local unit <Lo> on top and the remote unit <Re> on the
bottom. Each horizontal screen is again divided vertically, with alarm indicators, optical and power statuses
on the left and the Fast Ethernet trunk and tributary cards on the right. Use [F1] to toggle between local and
remote unit. Use the [F2], [F3], [F4] or [F5] to edit the tributary card settings.
4.1.5 E1/T1 Tributary Card Configuration
In this example we have a 4xT1 in slot 1, FXO/FXS Voice card in slot 2, and 4xE1 cards in slots 3 & 4.
Press the [F2] key to edit slot 1.
Use the function keys [F1], [F3]~[F5] to select the configuration menu items, use the "space bar" to toggle
the different parameters for each setting. Press [F1] for 'Service Mode' and press "space" to toggle service
between "OOS" and "IS" (OOS=Out of Service, IS=In Service). Press [F2] and "space" until the parameter
is "Unframed". Finally press [F2] to confirm.
System Name: Equipment Status Monitoring
+-----------------------------------------------------------------------------+
|<Lo> HwVer: 1.0.3| Optical | TB CH/ETH 1/LINK 2/FDX 3/100M 4/10M |
| MAJ: R PWR: G | [OE1] [OE2] | LAN 1 - - - - |
| MIN: - LCK: - | LSR: Y LSR: Y | LAN 2 - - - - |
| LBK: - RNG: - | LOS: - LOS: - | LAN M - - - - |
| RDI: - ACO: - | WK: G WK: - | TB1/G 4xT1S G G G G |
|----------------------------------| TB2/G 4xFXO - - - - |
| [PWR1]: F [FAN]: - [ExtAlm1]: L | TB3/G4xE1S/B G G G G |
| [PWR2]: - [ExtAlm2]: L | TB4/G4xE1S/B G G G G |
+-----------------------------------------------------------------------------+
|<Re> HwVer: | Optical | TB CH/ETH 1/LINK 2/FDX 3/100M 4/10M |
| MAJ: R PWR: G | [OE1] [OE2] | LAN 1 |
| MIN: LCK: | LSR: Y LSR: Y | LAN 2 |
| LBK: RNG: | LOS: LOS: | LAN M |
| RDI: ACO: | WK: G WK: | TB1/G 4xT1S G G G G |
|----------------------------------| TB2/G 4xFXS |
| [PWR1]: F [FAN]: [ExtAlm1]: L | TB3/G4xE1S/B G G G G |
| [PWR2]: [ExtAlm2]: L | TB4/G4xE1S/B G G G G |
+-----------------------------------------------------------------------------+
+-----------------------------------------------------------------------------+
|Lo->Re[F1] TB1 Edit[F2] TB2 Edit[F3] TB3 Edit[F4] TB4 Edit[F5] Back[ESC]|
+-----------------------------------------------------------------------------+
System Name: T1 Parameters Slot Editing
Location : Local /Slot 1
All channels will be set as:
[F1] Service Mode : OOS
[F3] Frame Type : ESF
[F4] Line Coding : B8ZS
[F5] LBO Setting : 0-133 ft
+-----------------------------------------------------------------------+
| Confirm[F2] Back[ESC] |
+-----------------------------------------------------------------------+