Technical data
77
CTC EcoZenith i250
Installation
!
The maximum power
output must be
written on the rating
plate with a marker.
!
Save these settings
under: Installer/
Settings/Save
settings
First start
Switch on the power using the safety switch. The display comes on.
CTC EcoZenith i250 now asks the following:
1. Select the language and press next.
2. Confirm that the system is filled with water and press OK. Press next.
3. Size of main fuse Choose between 10 and 35 A.
4. Specify the maximum electric heater power. Choose between 0.0 and
9.0 kW in different steps.
(This value does not lock the supply, but the value can be changed in
the settings menu.)
5. Select the option permitting the compressor (if the collector system is
ready or the air/water pump is already installed). When the compressor
is started for the first time, it is automatically checked that it is running in
the correct direction. An error message is displayed in the panel display
if it is rotating in the wrong direction. Switch any two phases to change
the direction of rotation. Use your hand to feel that the hot gas pipe
immediately becomes warm when the compressor starts, but bear in
mind that the pipe may be hot!
6. Specify the max. primary flow °C for radiator system 1.
7. Specify the inclination for radiator system 1.
8. Specify the adjustment for radiator system 2. If the primary flow sensor
for radiator system 2 is installed, repeat steps 7 to 9 for radiator system
2.
9. Current sensors identified. The CTC EcoZenith i250 then starts and the
start menu appears.