Technical data
34
CTC EcoZenith i250 
General Information
Adjustment
The adjustment means that the temperature level can 
be raised or lowered at a specific outdoor temperature. 
After this default setting, fine adjustment takes place in 
the “Room temperature” menu.
Room temp. reduced  -2 (0 to -40)
“Room temp. reduced” is displayed if a room sensor is 
installed. 
You define here how many degrees the room 
temperature will be reduced by during the various 
scheduled reduction periods, e.g. Night reduction, 
Holiday, etc. 
Prim reduced  -3 (0 to -40)
If there is no room sensor installed, “Prim reduced” is 
displayed instead.
Exact primary flow  No
Exact primary flow means that the heat pump never 
switches over and heats the upper tank (hot water 
charging). This is provided solely by the electric heater. 
In summer mode however, i.e. if the outdoor 
temperature is above the limit (Heating off, outside), the 
heat pump will be allowed to send water to the upper 
tank.
Example:
Room temp red -2 means that the room temperature is 
reduced by 2 °C from its normal temperature.
Example:
As a general rule, a Prim reduced value of 3-4 °C is 
equivalent to a 1 °C reduction in room temperature in a 
normal system.
8.7.2  Heat pump
Compressor   
Options: Permitted or Blocked. 
The product is supplied with a blocked compressor. 
When the compressor is blocked, the product operates 
like an electric boiler. All other functions are intact. 
Permitted means that the compressor is allowed to 
operate. 
Min. outdoor temp. °C  -15 (-22 to 0)
This menu is displayed only if the heat pump is an 
EcoAir model, and includes settings for the outdoor 
temperature at which the compressor is no longer 
permitted to operate. The heat pump starts 2°C above 
the set value. The lowest outdoor temperature required 
for start is -18°C. 
Brine pump on 10 days
Options 0 or 10 days. 
After installation is complete, you can choose to run the 
brine pump constantly for 10 days to remove air from 
the system.
1 2
1 2
T ºC
60
40
20
0
-20
16  20  0  4  8 12
Room temp.
Heating circuit 1
Night reduction Holiday
Room temp.
Heating circuit 1 (50)
Night reduction Holiday
Heat pump
Compressor Permitted
Min outdoor temp °C  -15
Brine pump on 10 days  0
Tariff HP  Off
Minimum run time  6
Electric heater
Boiler upper°C  50
Boiler upper add°C  57
Boiler upper extra DHW°C  60
Boiler upper max kW  5.5
Boiler lower °C  55
Boiler lower max kW  6.0
Delay mixing valve  180
Main fuse A  25
Input voltage  3x400 V
Upper tank
Stop temp HP°C  Max
Start/stop diff upper ºC  7
Max time upper tank  20
Max time lower tank  40
Communication
MB address  1
Baud rate  9600
Parity  even
Stop bit  1
Save settings
Save settings?
Def Heat pump
Heat pump  Off
Flow/level switch  None
Test Heating circuit
Mixing valve1  Open
Rad pump1  On
Mixing valve2  Off
Rad pump2  Off
LED room sensor  On
Test valves
Test Elec.heater
3-way valve  Down
Electric heater L1A  Off
Electric heater L1B  Off
Electric heater L2A  Off 
Electric heater L2B  Off
Electric heater L3A  Off
Electric heater L3B  Off
Electric heater A13  Off
Alarm log 
Latest alarm:  Time  HP (b)  LP (b)  SH (K)  I(A)
Low brine flow  07:20 6/3  8.8  3.3  15.9  3.9
Stored alarms:
Wrong phase order  10:30 1/3  27.9  8.6  -227  50.0
Comm. error motor protect  09:01 1/3 27.9  3.6  42.2 
0.0
Factory settings coded
Code  0 0 0 0
Upper tank 
Lower tank
Compressor operation
Expansion valve
Log compressor stop
Operation data heating 2
Out  Room1 Prim1  Return Room2  Prim2
Test Heat pump
HP Compr.  Off
HP Brine p/Fan  Off
HP Charge p  0
Defrost Manually  Off
Compressor heat  Off
Drip tray heater  Off
Heating Cable  Off
4-way valve(Y11)  Off