Technical data
34
CTC EcoZenith i250
General Information
Adjustment
The adjustment means that the temperature level can
be raised or lowered at a specific outdoor temperature.
After this default setting, fine adjustment takes place in
the “Room temperature” menu.
Room temp. reduced -2 (0 to -40)
“Room temp. reduced” is displayed if a room sensor is
installed.
You define here how many degrees the room
temperature will be reduced by during the various
scheduled reduction periods, e.g. Night reduction,
Holiday, etc.
Prim reduced -3 (0 to -40)
If there is no room sensor installed, “Prim reduced” is
displayed instead.
Exact primary flow No
Exact primary flow means that the heat pump never
switches over and heats the upper tank (hot water
charging). This is provided solely by the electric heater.
In summer mode however, i.e. if the outdoor
temperature is above the limit (Heating off, outside), the
heat pump will be allowed to send water to the upper
tank.
Example:
Room temp red -2 means that the room temperature is
reduced by 2 °C from its normal temperature.
Example:
As a general rule, a Prim reduced value of 3-4 °C is
equivalent to a 1 °C reduction in room temperature in a
normal system.
8.7.2 Heat pump
Compressor
Options: Permitted or Blocked.
The product is supplied with a blocked compressor.
When the compressor is blocked, the product operates
like an electric boiler. All other functions are intact.
Permitted means that the compressor is allowed to
operate.
Min. outdoor temp. °C -15 (-22 to 0)
This menu is displayed only if the heat pump is an
EcoAir model, and includes settings for the outdoor
temperature at which the compressor is no longer
permitted to operate. The heat pump starts 2°C above
the set value. The lowest outdoor temperature required
for start is -18°C.
Brine pump on 10 days
Options 0 or 10 days.
After installation is complete, you can choose to run the
brine pump constantly for 10 days to remove air from
the system.
1 2
1 2
T ºC
60
40
20
0
-20
16 20 0 4 8 12
Room temp.
Heating circuit 1
Night reduction Holiday
Room temp.
Heating circuit 1 (50)
Night reduction Holiday
Heat pump
Compressor Permitted
Min outdoor temp °C -15
Brine pump on 10 days 0
Tariff HP Off
Minimum run time 6
Electric heater
Boiler upper°C 50
Boiler upper add°C 57
Boiler upper extra DHW°C 60
Boiler upper max kW 5.5
Boiler lower °C 55
Boiler lower max kW 6.0
Delay mixing valve 180
Main fuse A 25
Input voltage 3x400 V
Upper tank
Stop temp HP°C Max
Start/stop diff upper ºC 7
Max time upper tank 20
Max time lower tank 40
Communication
MB address 1
Baud rate 9600
Parity even
Stop bit 1
Save settings
Save settings?
Def Heat pump
Heat pump Off
Flow/level switch None
Test Heating circuit
Mixing valve1 Open
Rad pump1 On
Mixing valve2 Off
Rad pump2 Off
LED room sensor On
Test valves
Test Elec.heater
3-way valve Down
Electric heater L1A Off
Electric heater L1B Off
Electric heater L2A Off
Electric heater L2B Off
Electric heater L3A Off
Electric heater L3B Off
Electric heater A13 Off
Alarm log
Latest alarm: Time HP (b) LP (b) SH (K) I(A)
Low brine flow 07:20 6/3 8.8 3.3 15.9 3.9
Stored alarms:
Wrong phase order 10:30 1/3 27.9 8.6 -227 50.0
Comm. error motor protect 09:01 1/3 27.9 3.6 42.2
0.0
Factory settings coded
Code 0 0 0 0
Upper tank
Lower tank
Compressor operation
Expansion valve
Log compressor stop
Operation data heating 2
Out Room1 Prim1 Return Room2 Prim2
Test Heat pump
HP Compr. Off
HP Brine p/Fan Off
HP Charge p 0
Defrost Manually Off
Compressor heat Off
Drip tray heater Off
Heating Cable Off
4-way valve(Y11) Off