Technical data
28
CTC EcoZenith i250
General Information
8.5 Operation
This menu displays current temperatures and the
operational data for your heating system.
Primary flow radiators
The temperature of the primary flow to the house’s
radiators is shown above the CTC EcoZenith i250
(42°C). This value will vary during the year according
to the parameters set and the current outdoor
temperature.
Return radiators
The return temperature of the radiator water returning to
EcoZenith is also shown above the CTC EcoZenith i250
(34°C). This value will vary during operation according to
the parameters set, the radiator system’s capacity and
the current outdoor temperature.
The screen shows operational data with the CTC EcoAir
connected. When the pumps are in operation, the pump icons
also rotate on screen.
Svenska Nederlands English Deutsch
Suomi Française Dansk Norsk
1 2
1 2
22,2 ºC 21,2 ºC 58 ºC -5 ºC
1 2
1 2
1 2
06 - 09 18 - 21
07 - 09 20 - 23
06 - 09 10 - 21
06 - -- -- - 21
06 - -- -- - 21
10 - 12 20 - 23
10 - 12 20 - 23
1 2
1 2
T ºC
60
40
20
0
-20
16 20 0 4 8 12
06-09 18-21
07-09 00-00
06-09 00-00
06-09 00-00
06-09 00-00
10-12 00-00
10-12 00-00
Room temp. DHW Operation Installer
CTC EcoZenith Monday 09:35
Night reduction Holiday
Heating circuit 2 (50)
Heating circuit 1
Room temp.
Start menu
Room temperature settings
Selecting DHW comfort
Heating system data
Installer settings menu
Extra
Hot water
0.0 hours
On
Temperature
Normal
Weekly schedule
DHW
Weekly program Day by day
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Weekly program DHW
Operation data system
Status HP upper tank
Tank upper°C 49 (60)
Tank lower°C 42 (45)
Primary flow°C 42 (43)
Return flow°C 34
Radiator pump On
Mixing valve Open
Delay mixing valve 180
Electric power kW 0.0 0.0 0.0
Current L1/L2/L3 0.0 0.0 0.0
Operation data EcoZenith
Stored oper data
Heating circuit 2
Operation data heating
Installer
Time/Language Settings Define system Service
Software display PCB: 20120205
Software HP PCB: 20120125
Installer
Installer
Time 21:34
Date 2012-02-05
Settings
Heating circuit
Heating circuit 1
Heating circuit 2
Heat pump
Electric heater
Upper tank
Remote control NR
Communication
Save settings
Load settings
Load factory settings
Max primary flow°C 55
Min primary flow°C Off
Heating off, out°C 18
Heating off 120
Inclination°C 50
Adjustment°C 0
Room temp reduced°C -2
or
Primary flow reduced°C -3
Define system
Def heating circuit
Heating circuit 1
Heating circuit 2
Heat pump
SMS
Cooling
Heating circuit 1 Yes
Room sensor 1 Yes
Type Wire
Service
Function test
Function test
Alarm log
Factory settings coded
Quick start compressor.
Software update, USB
Write log to USB
Control current sensors
Re-installation
Heating circuit
Heat pump
Valves
Electric heater
Total operation time h: 14196
Max primary flow°C: 51
Consumtion kWh 20
Compressor:
Operation time /24 h:m 00:00
Stored oper data
Heat pump
Compressor On
Charge pump On 47%
Brine pump On
HP in/out°C 35.5 / 42.3
Current L1 4.0
Night reduction heat circ.
Weekly program Day by day NR
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Night reduction heat circ.
Weekly program Block NR
Decrease Sunday 22:00
Increase Friday 14:00
Decrease -------- 00:00
Increase -------- 00:00
Holiday
Holiday period 3 days
Out Room1 Prim1 Return Room2 Prim2
Information
Press the information button to display
the operational data for the relevant
item.
Current outdoor temperature
Shows the current outdoor
temperature.
The product uses this value to
calculate the various operational
parameters.
1
2
Current indoor temperature
Shows the current room temperature
(if a room sensor is selected during
operation). If two radiator systems
are installed, the values for both are
displayed.
The screen also shows the incoming and
outgoing temperatures from the heat
pump installed.
HP out
At the right of the heat pump (42°C) the heat pump’s
outgoing temperature is shown.
HP in
At the right of the heat pump (34°C) the heat pump’s
return temperature is shown.
Brine in (CTC EcoPart only)
At the top left of the EcoPart (2°C) the brine’s current
temperature from the collector to CTC EcoPart is
shown.
Brine return (CTC EcoPart only)
The bottom left value (-1 °C) is the return temperature of
the brine going back into the collector hose. The values
vary during the year according to the heat source’s
capacity and the energy drawn out.
Operation data system
Define SMS
Activate GSM? Yes
Level of signal -------
Phone number 1 46704130901
Phone number 2 ---------------
Hardware version 1 1
Software version 1 5
Define Cooling
Cooling No
Common heating/cooling No
Condense pipe secured No
Room temp. cooling 25
Def heating circuit
Heating circuit 1 Yes
Room sensor 1 Yes
Type Wire
Def radiator system
Radiator system1 Yes
Room sensor Yes
Type Wireless
Room sensor Disconnect
Status Connected
Signal strength
Battery 85%
Version x0102
The screen shows operating information with the CTC EcoPart
connected. When the pumps are in operation, the pump icons
also rotate on screen.