Technical data
16
CTC EcoZenith i250 
General Information
6.  Control system
The CTC EcoZenith i250 has an advanced yet 
straightforward control system with a touchscreen on 
which all settings are entered directly.
The CTC EcoZenith i250 control system:
•  Monitors all system tank, heat pump and heating 
system functions
•  Permits individual settings
•  Displays desired values, such as temperatures, 
operation times, energy consumption and fault 
signals.
•  Facilitates the setting of values and troubleshooting 
in a simple and well-structured way.
Factory values
The CTC EcoZenith i250 is delivered with set factory 
values which are suitable for a standard house with 
a standard radiator system. The CTC EcoZenith i250 
automatically adjusts the water temperature to the 
primary flow’s current heating requirement. This is 
monitored by the control system, which continuously 
ensures that you are provided with optimum function 
and economy. These values are easy to change as and 
when required. Ask your installer to help you determine 
the correct values.
Heat pump
On delivery the CTC EcoZenith i250 is ready for 
connection to a CTC heat pump, CTC EcoAir 400 
outdoor air heat pump or CTC EcoPart 400 bedrock/
ground source heat pump. 
This means that the control system already contains all 
the controls for the heat pump. When the heat pump 
is connected, the EcoZenith i250 automatically goes 
to heat pump operation. Once this has taken place the 
menus for the heat pump are displayed. On delivery the 
compressor is blocked and must be set to permitted. 
This is done under the Installer/Settings/Heat pump 
menu.
Menu structure 
The product’s menus are described on the following 
pages. First there is an overview and then each menu is 
described in detail. 
 Svenska  Nederlands  English  Deutsch
 Suomi  Française  Dansk  Norsk
1 2
1 2
  22,2 ºC  21,2 ºC  58 ºC  -5 ºC
1 2
1 2
1 2
  06 - 09  18 - 21
  07 - 09  20 - 23
  06 - 09  10 - 21
 06 - --  -- - 21
 06 - --  -- - 21
  10 - 12  20 - 23
  10 - 12  20 - 23
1 2
1 2
T ºC
60
40
20
0
-20
16  20  0  4  8 12
06-09 18-21
07-09 00-00
06-09 00-00
06-09 00-00
06-09 00-00
10-12 00-00
10-12 00-00
  Room temp.  DHW  Operation  Installer
CTC EcoZenith  Monday 09:35
Night reduction Holiday
Heating circuit 2 (50)
Heating circuit 1
Room temp.
Start menu
Room temperature settings
Selecting DHW comfort
Heating system data
Installer settings menu
Extra
Hot water 
0.0 hours
On
Temperature
Normal
Weekly schedule
DHW
Weekly program  Day by day
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Weekly program DHW
Operation data system
Status  HP upper tank
Tank upper°C  49 (60)
Tank lower°C  42 (45)
Primary flow°C  42 (43)
Return flow°C  34
Radiator pump  On
Mixing valve  Open
Delay mixing valve  180
Electric power kW  0.0 0.0 0.0
Current L1/L2/L3  0.0 0.0 0.0
Operation data EcoZenith
Stored oper data
Heating circuit 2
Operation data heating
Installer
Time/Language  Settings  Define system  Service
Software display PCB:  20120205
Software HP PCB:  20120125
Installer
Installer
Time 21:34
Date 2012-02-05
Settings
Heating circuit
Heating circuit 1
Heating circuit 2
Heat pump
Electric heater
Upper tank
Remote control  NR
Communication
Save settings
Load settings
Load factory settings
Max primary flow°C  55
Min primary flow°C  Off
Heating off, out°C  18
Heating off  120
Inclination°C 50
Adjustment°C 0
Room temp reduced°C  -2
 or
Primary flow reduced°C  -3
Define system
Def heating circuit
Heating circuit 1
Heating circuit 2
Heat pump
SMS
Cooling
Heating circuit 1  Yes
Room sensor 1  Yes
Type Wire
Service
Function test
Function test
Alarm log
Factory settings coded
Quick start compressor.
Software update, USB
Write log to USB
Control current sensors
Re-installation
Heating circuit 
Heat pump
Valves
Electric heater
Total operation time h:  14196
Max primary flow°C:    51
Consumtion kWh    20
Compressor:
 Operation time /24 h:m  00:00
Stored oper data
Heat pump
Compressor On
Charge pump  On 47%
Brine pump  On
HP in/out°C  35.5 / 42.3
Current L1  4.0
Night reduction heat circ.
Weekly program  Day by day  NR
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Night reduction heat circ.
Weekly program  Block  NR
Decrease  Sunday 22:00
Increase  Friday 14:00
Decrease  -------- 00:00
Increase  -------- 00:00
Holiday
Holiday period  3 days
Out  Room1 Prim1  Return Room2  Prim2
 Svenska  Nederlands  English  Deutsch
 Suomi  Française  Dansk  Norsk
1 2
1 2
  22,2 ºC  21,2 ºC  58 ºC  -5 ºC
1 2
1 2
1 2
  06 - 09  18 - 21
  07 - 09  20 - 23
  06 - 09  10 - 21
 06 - --  -- - 21
 06 - --  -- - 21
  10 - 12  20 - 23
  10 - 12  20 - 23
1 2
1 2
T ºC
60
40
20
0
-20
16  20  0  4  8 12
06-09 18-21
07-09 00-00
06-09 00-00
06-09 00-00
06-09 00-00
10-12 00-00
10-12 00-00
  Room temp.  DHW  Operation  Installer
CTC EcoZenith  Monday 09:35
Night reduction Holiday
Heating circuit 2 (50)
Heating circuit 1
Room temp.
Start menu
Room temperature settings
Selecting DHW comfort
Heating system data
Installer settings menu
Extra
Hot water 
0.0 hours
On
Temperature
Normal
Weekly schedule
DHW
Weekly program  Day by day
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Weekly program DHW
Operation data system
Status  HP upper tank
Tank upper°C  49 (60)
Tank lower°C  42 (45)
Primary flow°C  42 (43)
Return flow°C  34
Radiator pump  On
Mixing valve  Open
Delay mixing valve  180
Electric power kW  0.0 0.0 0.0
Current L1/L2/L3  0.0 0.0 0.0
Operation data EcoZenith
Stored oper data
Heating circuit 2
Operation data heating
Installer
Time/Language  Settings  Define system  Service
Software display PCB:  20120205
Software HP PCB:  20120125
Installer
Installer
Time 21:34
Date 2012-02-05
Settings
Heating circuit
Heating circuit 1
Heating circuit 2
Heat pump
Electric heater
Upper tank
Remote control  NR
Communication
Save settings
Load settings
Load factory settings
Max primary flow°C  55
Min primary flow°C  Off
Heating off, out°C  18
Heating off  120
Inclination°C 50
Adjustment°C 0
Room temp reduced°C  -2
 or
Primary flow reduced°C  -3
Define system
Def heating circuit
Heating circuit 1
Heating circuit 2
Heat pump
SMS
Cooling
Heating circuit 1  Yes
Room sensor 1  Yes
Type Wire
Service
Function test
Function test
Alarm log
Factory settings coded
Quick start compressor.
Software update, USB
Write log to USB
Control current sensors
Re-installation
Heating circuit 
Heat pump
Valves
Electric heater
Total operation time h:  14196
Max primary flow°C:    51
Consumtion kWh    20
Compressor:
 Operation time /24 h:m  00:00
Stored oper data
Heat pump
Compressor On
Charge pump  On 47%
Brine pump  On
HP in/out°C  35.5 / 42.3
Current L1  4.0
Night reduction heat circ.
Weekly program  Day by day  NR
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Night reduction heat circ.
Weekly program  Block  NR
Decrease  Sunday 22:00
Increase  Friday 14:00
Decrease  -------- 00:00
Increase  -------- 00:00
Holiday
Holiday period  3 days
Out  Room1 Prim1  Return Room2  Prim2
Operation data system
Define SMS
Activate GSM?  Yes
Level of signal  -------
Phone number 1  46704130901
Phone number 2  ---------------
Hardware version  1 1
Software version  1 5
Define Cooling
Cooling No
Common heating/cooling  No
Condense pipe secured  No
Room temp. cooling  25
Def heating circuit
Heating circuit 1  Yes
Room sensor 1  Yes
Type Wire
Def radiator system
Radiator system1  Yes
Room sensor  Yes
Type Wireless
Room sensor  Disconnect
Status Connected
Signal strength
Battery 85%
Version x0102
The screen shows operating information with 
the CTC EcoAir heat pump connected.
The screen shows operating information with 
the CTC EcoPart heat pump connected.
Start menu










