Technical data
87  CTC EcoZenith i250
Installation CTC EcoAir 520M
15.1  Menu functions unique to the CTCEcoAir520M
Inverter_Inverter_Inverter_Inverter_Inverter_Inverter_Inverter_Inverter_
      00-06 22-24
      00-06 22-24
      00-06 22-24
      00-06 22-24
      00-06 23-24
      00-08 23-24
      00-08 22-24
      00-06 22-24
      00-06 22-24
      00-06 22-24
      00-06 22-24
      00-06 23-24
      00-08 23-24
      00-08 22-24
Settings Heat pump
Compressor:  Permitted
Min outtemp °C    -15
Tariff VP    Off
Cold temp limit    0
Max RPS    90
Warm temp limit    20
Max RPS warm temp    50
>>
Heat pump
Compressor  On 65 rps
Charge pump  On 47%
Fan On
HP in/out°C  35.5 / 42.3
Current L1  4.0
Settings Heat pump
<<
Max RPS silent mode    50
Silent mode
HS<>DHW time (sek)    120
Charge pump    50
Auto adj. charge pump
Set. Silent mode
Inst. Ljudreducering
Silent mode  Off
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Silent mode  On  Active
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Förslag Inst. Värmepump
Förslag Inst. Värmepump
Förslag Inst. Värmepump
The following menu functions are unique to heat pumps 
that use inverter technology. (CTC EcoAir 520M) 
15.1.1 Operation data heat pump
Compressor  On/Off/65 rps
This shows whether or not the heat pump is operating 
as well as showing the compressor speed (rps).
The compressor speed is automatically tailored to the 
energy requirement, up to the maximum permitted 
speed as determined by the outdoor temperature.
Charge pump  On/Off/47%
Display of the charge pump's operational status and 
speed as a percentage.
Fan  (On....Off)
Shows whether the fan is operating or not.
HP in/out °C
Shows the heat pump’s return and primary flow 
temperatures.
Current L1
Shows the current across the compressor (phase L1).
The CTC EcoZenith i250 is supplied with suitable factory settings for the CTC EcoAir 520M. 
Enertech AB recommend these for optimal operating economy.