Technical data

84
CTC EcoZenith i250
Installation
14.13 Component list, wiring diagram
No. Component.
A1 Display
A2 Relay/main card
B1 Primary flow sensor 1
B2 Primary flow sensor 2
B5 Upper tank sensor
B6 Lower tank sensor
B7 Return sensor
B11 Room sensor 1
B12 Room sensor 2
B15 Outdoor sensor NTC 150
B 46 Sensor external tank – Differential thermostat function.
COM HP Communication heat pump G51 = Brown cable, G52 = white cable, G53 = green cable.
E13 Backup heating thermostat E13
F1 Automatic circuit breaker 10 A
F2 Automatic circuit breaker HP 10 A
F10 Max. thermostat
G1 Radiator pump 1
G2 Radiator pump 2
G11 Charge pump 1
G46 Charge pump external tank – Differential thermostat function
H H-tank Main tank (EcoHeat/EcoZenith i250)
K1 Contactor 1
K2 Contactor 2
K19 Pressure/level switch
K20 Night red/circulation/extra DHW
X1 Terminal block, incoming supply
X10 Terminal block, HP supply Black connector
Y1 Mixing valve 1
Y2 Mixing valve 2
Y11 Non return valve
Y21 Diverting valve DHW
Y22 Diverting valve DHW
Y98 Expansion tank
Y99 Expansion tank