Circulation pump, radiator system (G1) (G2)
The circulation pump is fitted on the boiler’s primary flow and must be 
connected electrically from the boiler; see chapter on Electrical installation.
Mixing valve DHW (65)
Install a mixing valve for the hot tap water in order to avoid the risk of 
scalding.
Safety valve DHW (93)
Fit the enclosed valve to the incoming cold water connection. Connect the 
waste pipe to the waste system directly to the floor gully or, if the distance is 
more than two metres, to a funnel. The waste pipe must slope towards the 
waste system, be installed frost-free and left open to the atmosphere/without 
pressure.
Non-return valve (48)
Fit the non-return valve to the incoming cold water connection.
Shut-off valve (94)
It is important to fit a shut-off valve (94) to both the primary and return flows.
Boiler safety valve (92)
The boiler’s safety valve (2.5 bar) is fitted in the factory on the left side of the 
top. Connect the waste pipe to the waste system directly to the floor gully 
or, if the distance is more than two metres, to a funnel. The waste pipe must 
slope towards the waste system, be installed frost-free and left open to the 
atmosphere/without pressure.
Filling valve for radiator system (90)
Fit a filling valve between the cold water connection and the radiator return 
pipe, or between the cold water pipe and the expansion pipe. Observe the 
building regulations of the Swedish National Board of Housing, Building and 
Planning (Boverket) and the standard SS-EN 1717.
Manometer system pressure (95)
Fit the manometer on the expansion pipe or radiator return pipe.
Electric shut-off valve (47)
If the sub-mixing valve (radiator system 2) is to operate in the summertime 
while radiator system 1 is switched off, the system can be supplemented 
by an electric shut-off valve that closes the flow through the switching off of 
radiator pump (G1).
!
NB: The waste pipe 
must be fitted to the 
waste system.
!
NB: It is important to 
fit a shut-off valve (94) 
to both the primary 
and return flows.