10.2  Alarm texts
If a fault occurs with a sensor, for instance, an alarm is triggered. A message 
appears on the display with information about the fault.
You reset the alarm by pressing the Reset alarm button on the display. 
If several alarms are triggered, they are displayed one after the other. An 
outstanding fault cannot be reset without being rectified first. Some alarms 
are reset automatically if the fault disappears.
The description below also includes an alarm for connected heat pump.
Alarm text Description
Wrong phase order 
compressor
The product’s compressor motor must rotate in the right direction. The 
product checks that the phases are connected correctly; otherwise, an 
alarm is triggered. In this case, two of the phases to the product need to be 
changed. The power supply to the system must be shut off when rectifying 
this fault. This fault generally only occurs during installation.
Alarm sensor An alarm is displayed if a fault occurs with a sensor that is not connected or 
has short-circuited and if the value is outside the sensor's range. If this sensor 
is important to the system’s operation, the compressor stops. In this case, 
the alarm is reset manually after the fault has been rectified. For the following 
sensors the alarm is reset automatically after correction: 
Sensor upper tank (B5), Sensor lower tank (B6), Sensor prim flow 1 (B1), 
Sensor prim flow 2 (B2), Sensor out (B15), Room sensor 1 (B11), Room 
sensor 2 (B12), Sensor brine out, Sensor brine in, Sensor HPin, Sensor HPout, 
Sensor discharge, Sensor suction gas, Sensor high pressure, Sensor low 
pressure.
Motor protect compressor High/low current has been detected to the compressor. Press reset and 
check whether the alarm recurs. If the fault recurs, contact your installer.
High pressure switch The refrigerant’s high pressure switch has been triggered. Press reset and 
check whether the alarm recurs. If the fault recurs, contact your installer.
Low brine temp Incoming brine temperatures from borehole/ground loop are too low. Press 
reset and check whether the alarm recurs. If the fault recurs, contact your 
installer to check the dimensions of the cold side.
   Alarm: Wrong phase order 
compressor 
 Reset alarm