Technical data
43  CTC EcoZenith i250
General Information
8.8.3 Define CTC SMS (accessory)
This is for defining whether SMS control is installed 
(accessory).
Activate  Yes (Yes/No)
If “Yes”, the menus below will be displayed.
Level of signal 
The level of signal of the reception is shown here.
Phone Number 1 
The first activated phone number is shown here.
Phone Number 2 
The second activated phone number is shown here.
Hardware Version 
The hardware version of the SMS accessory is shown 
here.
Software version 
The software version of the SMS accessory is shown 
here.
NB: For more information on the SMS function, see the 
“CTC SMS” manual.
1 2
  Dansk  Nederlands  Čeština
  Svenska  Norsk  English
  Eesti  Polski  Slovenščina
  Deutsch  Suomi  Française
Operation data system
Define Cooling
Cooling   No
Common heating/cooling  No
Condense pipe secured  No
Room temp. cooling    25.0
Def heating circuit 1
Heating circuit 1    Yes
Room sensor 1    Yes
Type    Wire
Def heating circuit 1
Heating circuit 1      Yes
Room sensor 1      Yes
Type      Wireless
Action   
Disconnect
Status   
Associated
Level of signal
Battery     85%
Version     x0102
Def CTC SMS
Activate      Yes
Level of signal 
Phone Number 1  +46712345678
Phone Number 2  -----------------
Hardware Version   1 1
Software Version    1 9
Pump H-tank (G46)      Off
Temperatures
H-tank (B6) ºC      32
Test Diff thermostat function
Charge start diff temp ºC
7
Charge stop diff temp ºC
3
Charge temperature °C    60
Sett. Diff termostat function
Holiday
Cooling    20.2 (20.0)
Heating circuit 1    20.2 (20.0)
Room temp.
Night reduction
Op. Heating Circuit
Primary flow1 ºC  33(34)
Return flow ºC  31
Radiator pump  Till
Mixing valve  Open
Delay mixing valve  180
Primary flow 2ºC  33(34)
Radiator pump 2  Från
Mixing valve 2 
Settings language
Settings language
Def CTC SMS
Activate      Yes
Level of signal 
Phone Number 1  +46712345678
Phone Number 2  -----------------
Hardware Version   1 1
Software Version    1 9
8.8.4 Define cooling (accessory)
(Only applies to EcoPart.)
Cooling is adjusted using primary flow sensor 2 (B2), 
which means that radiator system 2 and cooling cannot 
be used simultaneously.
Common heating/cooling  No
Cooling  No (No/Yes)
This is for selecting whether cooling is installed.
Condense pipe secured  No (No/Yes)
If a condense pipe for the system has been secured, 
significantly lower temperatures are permitted at 
various points in the system. WARNING Build-up of 
condensation in the house structure can lead to damp 
and damage from mildew.
(No) means a setting range for room temperature of 
18–30ºC and (Yes) means a setting range of 10–30ºC
In the event of doubt, contact an expert surveyor for an 
assessment.
Room temperature cooling  25 (10 or 18...30)
This is used to set the desired room temperature for 
cooling. 
See the CTC EcoComfort manual for more 
information.