Technical data
43 CTC EcoZenith i250
General Information
8.8.3 Define CTC SMS (accessory)
This is for defining whether SMS control is installed
(accessory).
Activate Yes (Yes/No)
If “Yes”, the menus below will be displayed.
Level of signal
The level of signal of the reception is shown here.
Phone Number 1
The first activated phone number is shown here.
Phone Number 2
The second activated phone number is shown here.
Hardware Version
The hardware version of the SMS accessory is shown
here.
Software version
The software version of the SMS accessory is shown
here.
NB: For more information on the SMS function, see the
“CTC SMS” manual.
1 2
Dansk Nederlands Čeština
Svenska Norsk English
Eesti Polski Slovenščina
Deutsch Suomi Française
Operation data system
Define Cooling
Cooling No
Common heating/cooling No
Condense pipe secured No
Room temp. cooling 25.0
Def heating circuit 1
Heating circuit 1 Yes
Room sensor 1 Yes
Type Wire
Def heating circuit 1
Heating circuit 1 Yes
Room sensor 1 Yes
Type Wireless
Action
Disconnect
Status
Associated
Level of signal
Battery 85%
Version x0102
Def CTC SMS
Activate Yes
Level of signal
Phone Number 1 +46712345678
Phone Number 2 -----------------
Hardware Version 1 1
Software Version 1 9
Pump H-tank (G46) Off
Temperatures
H-tank (B6) ºC 32
Test Diff thermostat function
Charge start diff temp ºC
7
Charge stop diff temp ºC
3
Charge temperature °C 60
Sett. Diff termostat function
Holiday
Cooling 20.2 (20.0)
Heating circuit 1 20.2 (20.0)
Room temp.
Night reduction
Op. Heating Circuit
Primary flow1 ºC 33(34)
Return flow ºC 31
Radiator pump Till
Mixing valve Open
Delay mixing valve 180
Primary flow 2ºC 33(34)
Radiator pump 2 Från
Mixing valve 2
Settings language
Settings language
Def CTC SMS
Activate Yes
Level of signal
Phone Number 1 +46712345678
Phone Number 2 -----------------
Hardware Version 1 1
Software Version 1 9
8.8.4 Define cooling (accessory)
(Only applies to EcoPart.)
Cooling is adjusted using primary flow sensor 2 (B2),
which means that radiator system 2 and cooling cannot
be used simultaneously.
Common heating/cooling No
Cooling No (No/Yes)
This is for selecting whether cooling is installed.
Condense pipe secured No (No/Yes)
If a condense pipe for the system has been secured,
significantly lower temperatures are permitted at
various points in the system. WARNING Build-up of
condensation in the house structure can lead to damp
and damage from mildew.
(No) means a setting range for room temperature of
18–30ºC and (Yes) means a setting range of 10–30ºC
In the event of doubt, contact an expert surveyor for an
assessment.
Room temperature cooling 25 (10 or 18...30)
This is used to set the desired room temperature for
cooling.
See the CTC EcoComfort manual for more
information.