Technical data
41  CTC EcoZenith i250
General Information
1 2
1 2
T ºC
60
40
20
0
-20
16  20  0  4  8 12
Radiatorsystem forts
  58 ºC  -5 ºC
Info golvtorkning estricht
Room temp.
Heating circuit 1
Night reduction Holiday
Room temp.
Heating circuit 1 (50)
Night reduction Holiday
Set. heat pump
Compressor   Permitted
1
Min outdoor temp °C  -15
2
Brine pump on    Auto
Tariff HP    Off
Minimum run time    6
Electric heater
Boiler upper°C    50
Boiler upper add°C    57
Boiler upper extra DHW°C  60
Boiler upper max kW    5.5
Boiler lower °C    55
Boiler lower max kW    6.0
Delay mixing valve    180
Main fuse A    25
Input voltage    3x400 V
Tariff EL    Off
Upper tank
Stop temp HP°C    Max
Start/stop diff upper ºC  7
Max time upper tank    20
Max time lower tank    40
Communication
MB address    1
Baud rate    9600
Parity   even
Stop bit    1
Installer
Save settings
Save settings
Load factory settings
Def Heat pump
Heat pump  Off
Flow/level switch  None
Test Heating circuit
Mixing valve1    Open
Rad pump1    On
Mixing valve2    Off
Rad pump2    Off
LED room sensor    On
Test valves
Test Elec.heater
3-way valve    Down
Electric heater L1A    Off
Electric heater L1B    Off
Electric heater L2A    Off
Electric heater L2B    Off
Electric heater L3A    Off
Electric heater L3B    Off
Electric heater A13    Off
Alarm log 
Latest alarm:  Time  HP (b) LP (b)  SH (K) I(A)
Low brine flow  07:20 6/3  8.8  3.3  15.9  3.9
Stored alarms:
Wrong phase order  10:30 1/3  27.9  8.6  -227  50.0
Com. err m. protect 09:01 1/3  27.9  3.6  42.2  0.0
Factory settings coded
Code  0 0 0 0
Upper tank 
Lower tank
Compressor operation
Expansion valve
Log compressor stop
Cooling
Operation data heating 2
Out  Room1 Prim1  Return Room2  Prim2
Test Heat pump
HP Compr.    Off
HP Brine p/Fan    Off
HP Charge p    0
Defrost Manually    Off
Compressor heat    Off
Drip tray heater    Off
Heating Cable    Off
4-way valve(Y11)    Off
Inst. Radiatorsystem1
<<
Anti Water Hammer    No
HP max DHW    Yes
Drying period mode    Off
Drying period temp ºC  25
 Room temp.  DHW  Operation  Installer
  Drying period activ  1  /  12  (25)
CTC EcoZenith  Monday 09:35
1 2
  Dansk  Nederlands  Čeština
  Svenska  Norsk  English
  Eesti  Polski  Slovenščina
  Deutsch  Suomi  Française
Operation data system
Define Cooling
Cooling   No
Common heating/cooling  No
Condense pipe secured  No
Room temp. cooling    25.0
Def heating circuit 1
Heating circuit 1    Yes
Room sensor 1    Yes
Type    Wire
Def heating circuit 1
Heating circuit 1      Yes
Room sensor 1      Yes
Type      Wireless
Action   
Disconnect
Status   
Associated
Level of signal
Battery     85%
Version     x0102
Def CTC SMS
Activate      Yes
Level of signal 
Phone Number 1  +46712345678
Phone Number 2  -----------------
Hardware Version   1 1
Software Version    1 9
Pump H-tank (G46)      Off
Temperatures
H-tank (B6) ºC      32
Test Diff thermostat function
Charge start diff temp ºC
7
Charge stop diff temp ºC
3
Charge temperature °C    60
Sett. Diff termostat function
Holiday
Cooling    20.2 (20.0)
Heating circuit 1    20.2 (20.0)
Room temp.
Night reduction
Op. Heating Circuit
Primary flow1 ºC  33(34)
Return flow ºC  31
Radiator pump  Till
Mixing valve  Open
Delay mixing valve  180
Primary flow 2ºC  33(34)
Radiator pump 2  Från
Mixing valve 2 
Settings language
Settings language
8.7.10 Saving and loading settings
The following settings can be saved and loaded.
Save settings
Here your own settings can be stored; confirm with the 
"OK" button.
Load settings
The saved settings can be reloaded using this option. 
Load factory settings
The product is supplied with the factory values set. They 
can be restored by activating this function. Press OK 
to confirm. However, the product and product size are 
retained.
!
NB: If the expansion card has not 
been installed and Pool has been 
defined, the product will emit an 
alarm: 
Comm. fault expansion card.
8.7.8  Sett. Diff termostat function
The function must be defined before the settings can 
be entered. The operating thermostat function is used if 
you want to charge your system tank (e.g. EZ 250) from 
a water-jacketed stove, or another water source.
However, this function cannot be combined with the 
same function in a solar heating system (when e.g. an 
EcoTank is connected to an EZ 250). This is because 
the same outlets and sensors are used for both 
functions. 
Information about the operating thermostat function will 
be displayed under Operation data.
Charge start diff. temp., °C  7 (3...30)
Here you can set the temperature difference determining 
when charging from the heat source is started. The heat 
source must be this many degrees warmer than the 
tank temperature for charging to start.
Charge stop diff. temp., °C  3 (2...20) 
Here you can set the temperature difference determining 
when charging from the heat source is stopped. When 
the temperature difference between the product and the 
tank falls below this set value, charging stops.
Charge temperature, °C  60 (10...80)
Here you can set EcoZenith/EcoHeat's maximum 
permitted temperature in the lower tank. The charging 
stops if this temperature is exceeded.
8.7.9  Pool
The settings for Pool require the installation of an 
expansion card. 
See the CTC Solar controls/Expansion card manual for 
more information.