Technical data
40
CTC EcoZenith i250 
General Information
1 2
1 2
T ºC
60
40
20
0
-20
16  20  0  4  8 12
Radiatorsystem forts
  58 ºC  -5 ºC
Info golvtorkning estricht
Room temp.
Heating circuit 1
Night reduction Holiday
Room temp.
Heating circuit 1 (50)
Night reduction Holiday
Set. heat pump
Compressor   Permitted
1
Min outdoor temp °C  -15
2
Brine pump on    Auto
Tariff HP    Off
Minimum run time    6
Electric heater
Boiler upper°C    50
Boiler upper add°C    57
Boiler upper extra DHW°C  60
Boiler upper max kW    5.5
Boiler lower °C    55
Boiler lower max kW    6.0
Delay mixing valve    180
Main fuse A    25
Input voltage    3x400 V
Tariff EL    Off
Upper tank
Stop temp HP°C    Max
Start/stop diff upper ºC  7
Max time upper tank    20
Max time lower tank    40
Communication
MB address    1
Baud rate    9600
Parity   even
Stop bit    1
Installer
Save settings
Save settings
Load factory settings
Def Heat pump
Heat pump  Off
Flow/level switch  None
Test Heating circuit
Mixing valve1    Open
Rad pump1    On
Mixing valve2    Off
Rad pump2    Off
LED room sensor    On
Test valves
Test Elec.heater
3-way valve    Down
Electric heater L1A    Off
Electric heater L1B    Off
Electric heater L2A    Off
Electric heater L2B    Off
Electric heater L3A    Off
Electric heater L3B    Off
Electric heater A13    Off
Alarm log 
Latest alarm:  Time  HP (b) LP (b)  SH (K) I(A)
Low brine flow  07:20 6/3  8.8  3.3  15.9  3.9
Stored alarms:
Wrong phase order  10:30 1/3  27.9  8.6  -227  50.0
Com. err m. protect 09:01 1/3  27.9  3.6  42.2  0.0
Factory settings coded
Code  0 0 0 0
Upper tank 
Lower tank
Compressor operation
Expansion valve
Log compressor stop
Cooling
Operation data heating 2
Out  Room1 Prim1  Return Room2  Prim2
Test Heat pump
HP Compr.    Off
HP Brine p/Fan    Off
HP Charge p    0
Defrost Manually    Off
Compressor heat    Off
Drip tray heater    Off
Heating Cable    Off
4-way valve(Y11)    Off
Inst. Radiatorsystem1
<<
Anti Water Hammer    No
HP max DHW    Yes
Drying period mode    Off
Drying period temp ºC  25
 Room temp.  DHW  Operation  Installer
  Drying period activ  1  /  12  (25)
CTC EcoZenith  Monday 09:35
8.7.5  Remote control
Shows the type of remote control selected. 
“NR” = Remote night reduction, e.g. via the minicall 
system. SO = Ripple control. Disconnecting the 
compressor and immersion heater during a certain 
period which is defined by the electrical supplier (special 
equipment). 
DHW = Extra hot water, used along with the Extra DHW 
button.
8.7.6  Communication
These settings are activated for the Superior systems 
and are not used in normal operation. They are not 
described in these instructions.
!
NB: If the expansion card has not 
been installed and solar panels are 
defined, the product will emit an 
alarm: 
Comm. fault expansion card.
8.7.7  Solar panels (accessories)
These settings are intended for accessory solar panels. 
See the CTC Solar controls/Expansion card manual for 
more information.