Technical data

30
CTC EcoZenith i250
General Information
8.5.2 Operation Heating circuit
Primary flow 1 °C
Shows the temperature supplied to the system’s
radiators, along with the temperature which the system
is trying to achieve. This value will vary during the
year according to the parameters set and the current
outdoor temperature.
Return flow °C
Shows the temperature of the water returning from the
radiator system to the CTC EcoZenith i250.
Radiator pump
Shows the radiator pump’s operational status.
Mixing valve
Shows whether the mixing valve increases (opens) or
reduces (closes) the heat supplied to the radiators.
When the correct temperature has been achieved
with the mixing valve, the valve’s motor then remains
stationary.
Delay mixing valve
A microswitch in the mixing valve’s motor ensures that
auxiliary heating is not used unnecessarily, for example,
when ventilating a room or if the temperature (outdoors)
occasionally drops during the night. The mixing valve
is delayed for the time period selected before auxiliary
heating is used. The screen shows the countdown of
the delay in minutes. If “Blocked” is shown, never open
the mixing valve to the immersion heaters of the upper
tank.
Primary flow 2 ºC etc...
Displayed if radiator system 2 or Cooling has been
defined
1 2
Dansk Nederlands Čeština
Svenska Norsk English
Eesti Polski Slovenščina
Deutsch Suomi Française
Operation data system
Define Cooling
Cooling No
Common heating/cooling No
Condense pipe secured No
Room temp. cooling 25.0
Def heating circuit 1
Heating circuit 1 Yes
Room sensor 1 Yes
Type Wire
Def heating circuit 1
Heating circuit 1 Yes
Room sensor 1 Yes
Type Wireless
Action
Disconnect
Status
Associated
Level of signal
Battery 85%
Version x0102
Def CTC SMS
Activate Yes
Level of signal
Phone Number 1 +46712345678
Phone Number 2 -----------------
Hardware Version 1 1
Software Version 1 9
Pump H-tank (G46) Off
Temperatures
H-tank (B6) ºC 32
Test Diff thermostat function
Charge start diff temp ºC
7
Charge stop diff temp ºC
3
Charge temperature °C 60
Sett. Diff termostat function
Holiday
Cooling 20.2 (20.0)
Heating circuit 1 20.2 (20.0)
Room temp.
Night reduction
Op. Heating Circuit
Primary flow1 ºC 33(34)
Return flow ºC 31
Radiator pump Till
Mixing valve Open
Delay mixing valve 180
Primary flow 2ºC 33(34)
Radiator pump 2 Från
Mixing valve 2
Settings language
Settings language
Diff func.Pump/Temp. ºC
Differential thermostat function
Shows whether charge pump (G46) is switched on (ON,
OFF). Displays temperature of external tank. ºC (B46)
Pool ºC Off 23 (22)
Pool function
Shows whether pumps (G50,G51) are switched on (ON,
OFF). Displays pool temperature and (setpoint)
!
If the expansion card has not been
installed and Pool has been defined,
the product will emit an alarm:
Comm. fault expansion card.