Technical data
30
CTC EcoZenith i250 
General Information
8.5.2 Operation Heating circuit
Primary flow 1 °C
Shows the temperature supplied to the system’s 
radiators, along with the temperature which the system 
is trying to achieve. This value will vary during the 
year according to the parameters set and the current 
outdoor temperature.
Return flow °C
Shows the temperature of the water returning from the 
radiator system to the CTC EcoZenith i250.
Radiator pump
Shows the radiator pump’s operational status.
Mixing valve
Shows whether the mixing valve increases (opens) or 
reduces (closes) the heat supplied to the radiators. 
When the correct temperature has been achieved 
with the mixing valve, the valve’s motor then remains 
stationary.
Delay mixing valve
A microswitch in the mixing valve’s motor ensures that 
auxiliary heating is not used unnecessarily, for example, 
when ventilating a room or if the temperature (outdoors) 
occasionally drops during the night. The mixing valve 
is delayed for the time period selected before auxiliary 
heating is used. The screen shows the countdown of 
the delay in minutes. If “Blocked” is shown, never open 
the mixing valve to the immersion heaters of the upper 
tank.
Primary flow 2 ºC etc...
Displayed if radiator system 2 or Cooling has been 
defined
1 2
  Dansk  Nederlands  Čeština
  Svenska  Norsk  English
  Eesti  Polski  Slovenščina
  Deutsch  Suomi  Française
Operation data system
Define Cooling
Cooling   No
Common heating/cooling  No
Condense pipe secured  No
Room temp. cooling    25.0
Def heating circuit 1
Heating circuit 1    Yes
Room sensor 1    Yes
Type    Wire
Def heating circuit 1
Heating circuit 1      Yes
Room sensor 1      Yes
Type      Wireless
Action   
Disconnect
Status   
Associated
Level of signal
Battery     85%
Version     x0102
Def CTC SMS
Activate      Yes
Level of signal 
Phone Number 1  +46712345678
Phone Number 2  -----------------
Hardware Version   1 1
Software Version    1 9
Pump H-tank (G46)      Off
Temperatures
H-tank (B6) ºC      32
Test Diff thermostat function
Charge start diff temp ºC
7
Charge stop diff temp ºC
3
Charge temperature °C    60
Sett. Diff termostat function
Holiday
Cooling    20.2 (20.0)
Heating circuit 1    20.2 (20.0)
Room temp.
Night reduction
Op. Heating Circuit
Primary flow1 ºC  33(34)
Return flow ºC  31
Radiator pump  Till
Mixing valve  Open
Delay mixing valve  180
Primary flow 2ºC  33(34)
Radiator pump 2  Från
Mixing valve 2 
Settings language
Settings language
Diff func.Pump/Temp. ºC 
Differential thermostat function 
Shows whether charge pump (G46) is switched on (ON, 
OFF). Displays temperature of external tank. ºC (B46)
Pool ºC  Off 23 (22)
Pool function 
Shows whether pumps (G50,G51) are switched on (ON, 
OFF). Displays pool temperature and (setpoint)
!
If the expansion card has not been 
installed and Pool has been defined, 
the product will emit an alarm: 
Comm. fault expansion card.